9024-065-Q-8-16
Sec:A4
16.5”
28”
19”
WARNING
MOVING GATE CAN CAUSE
Persons are to keep clear! The gate is capable of
being moved without prior warning.
Do not let children operate the gate or play in the
gate area.
This entrance is for vehicles only. Pedestrians
must use a separate entrance.
Persons are to read the owner’s manual and
safety instructions.
For gate operator using Type D entrapment
protection, an automatic closing device (such as a
timer, loop sensor or similar device) shall not be
employed.
SERIOUS INJURY OR DEATH
CLASS
CERTIFIED TO
CAN/CSA C22.2 NO. 247
CONFORMS TO
ANSI/UL-325
VEHICULAR GATE OPERATOR
HP
53382
MODEL
SERIAL
VOLTS
PHASE
AMPS
60 Hz
MAX GATE LOAD
DoorKing, Inc., Inglewood, CA
SPECIFICATIONS FOR MODEL 9024-080
Gate Frame
7.75”
4” Minimum
Chain Height:
Idler wheels in
top position.
Concrete Pad
Concrete Pad
Class of Operation
UL 325 Class I, II, III, IV
Type of Gate
Vehicular Slide Gates Only
Drive Sprocket Size
#40
Chain
Motor
Quadra Drive DC Motor
Power Input: Volts@Amps
115 VAC @ 1.8 Amps OR 230 VAC @ 0.9 Amps
Batteries
Two 12 Volt, 7.2 A/Hr (Standard)
Two 12 Volt, 18 A/Hr (Optional)
Maximum Gate Cycles
AC Power: Continuous
Battery Power - 12 Volt, 7.2 A/Hr (Standard): 40 Cycles
Battery Power - 12 Volt, 18 A/Hr (Optional): 150 Cycles
Gate Speed
1
Ft/Sec
Max Gate Weight
1,000 Lbs - 453.6 Kg (Gate installed level in good working condition)
Max Gate Length
40 Ft - 12.2 Meters (Gate installed level in good working condition)
Inherent Entrapment
Protection Device
Inherent Reverse Sensor System (Type A)
External Entrapment
Protection Device Inputs
Connection inputs for Non-contact Sensor - Photo Sensor (Type B1)
(Monitored Inputs)
Connection input for Contact Sensor - Reversing Edge (Type B2)
Use this manual for the Model 9024-080 operator with circuit board 4100-010 Rev AA or higher ONLY.
DoorKing, Inc. reserves the right to make changes in the products described in this manual without notice and without obligation of DoorKing, Inc. to notify any persons
of any such revisions or changes. Additionally, DoorKing, Inc. makes no representations or warranties with respect to this manual. This manual is copyrighted, all rights
reserved. No portion of this manual may be copied, reproduced, translated, or reduced to any electronic medium without prior written consent from DoorKing, Inc.
Battery Power Note:
The number of gate cycles when using
ONLY
battery
power
WILL
vary depending on gate weight, gate length, operating
condition of gate hardware, temperature and amount of charge in batteries.
OPTIONAL BATTERY
12 Volt 18 Amp/Hr
Battery for Extended
Back-Up Power
P/N 1801-004
Two (2) required.
STANDARD BATTERY
12 Volt 7.2 Amp/Hr
Standard
Replacement Battery
P/N 1801-003
Two (2) required.
TWO (2) Entrapment Protection Devices are REQUIRED
for UL 325 compliance.
Type B1 and B2 MUST be MONITORED when used.