5.1 Terminal Descriptions
SECTION 5 - MAIN TERMINAL WIRING
Low Voltage Common
Full Open
24 VDC - 250 mA max.
Open / Loop out
Low Voltage Common
Full Open
Low Voltage Common
Partial Open
Low Voltage Common
Reverse / Stop
Low Voltage Common
24 VDC Accessories / Maglock
Relay
Relay
Low Voltage Common
Bi-Parting
Bi-Parting
Common
Tracker Data
Tracker In
SW1,
switch 8
ON
: 24-VDC
Maglock
power is provided
except
when the gate is
opening
or
open
(Normally Closed function). 1 Amp Max.
3 Button Station
•
Use a standard
4-wire
3-button
control station.
DoorKing’s
3-wire
3-button
control station
cannot
be used.
•
When using a 3-button control
station, the 3-pin jumper MUST
be set to
ON
position.
•
See next page for wiring.
UL 325
See pages 24 - 26
3-Button
Station
Relay
Contacts
3 Button
LEDs
For long gate applications. An input
device connected to main terminal 8 will
open the gate to the partial open setting,
See page 22 for more information.
8
10
12
13 14
19 20
18
17
16
OPEN Beam Stop
CLOSE Beam Reverse
OPEN Edge/Beam Reverse
CLOSE Edge/Beam Reverse
Ground (Common)
Ground (Common)
OPEN
CLOSE
STOP
Common
•
lf SW 1,
switch 3
is
ON
, functions as a
normal full open input (Normal setting).
•
lf SW 1,
switch 3
is
OFF
, input to main
terminal 4 becomes the output from the
EXIT loop detector plugged into the EXIT
loop port. (Used for specialized functions).
ON
12
3
45678
SW 1
This input ONLY functions when gate is
fully
opened
or in the
closing cycle
.
•
When gate is closing: SW 1,
switch 4
is
OFF,
an input to main terminal 10 (eg: photo beam
gets obstructed) will
reverse
and open the gate.
Note:
If the auto-close timer is ON,
when gate reaches the open position,
timer will time out and close the gate.
•
When gate is closing: SW 1,
switch
4
is
ON,
an input to main terminal 10
(eg: photo beam gets obstructed) will
stop
the gate, then continue to close
the gate when input is clear (Used to
help prevent tailgating vehicles from unauthor-
ized entry). See page 21 for more information.
ON
12
3
4
5678
SW 1
Operation of relay is dependent on
setting of SW 1,
switches 6 and 7
.
Relay contacts
can be set for
Normally Open (NO) or Normally
Closed (NC) operation.
Contact rating is
1 amp maximum
at 24-volts DC.
ON
12
3
4
5
67
8
SW 1
NC
NO
4
OPEN
STOP
CL
OS
E
Connects to a
DoorKing Tracker Expansion
Board
. Data will be reported about this
gate
operator’s SPECIFIC activity
to a DoorKing
access control system. A list of the events
will be “Tracked” and stored in the access
control system.
Main T
erminal Input LEDs
#19
#20
W
4
5
Main Terminal Input
LEDs Note:
The LED
that is beside the main
terminal wiring input
will light when that
terminal input gets
activated.
Main Terminal Input LEDs
W
M
M
M
L
tha
WE
M
M
M
L
th
WE
M
M
M
M
L
L
L
L
th
h
E
M
M
M
M
L
L
L
L
th
h
h
h
E
M
M
M
M
L
L
L
th
h
h
E
M
M
M
L
L
L
th
E
E
M
M
L
t
ER
R
M
M
t
ER
R
M
R
R
R
R
#2
#4
#6
#8
#10
ON
1
2
34567
8
SW 1
SW1,
switch 8 OFF
: 24-VDC,
500 mA constant power can be
provided for desired accessories
wired to main terminal 12 when
the maglock is
NOT
used.
Photo
Sensor
Ma
glock
ON
OFF
Bi-Parting Gates ONLY.
Connect secondary gate operator
main terminals 16-17-18 to primary main terminal
16-17-18 respectively. 16 & 17 wires
MUST
be twisted
together.
Primary operator is determined by pressing its
KEY SWITCH
FIRST
after powering up operators.
This establishes Primary/Secondary operator order.
16 & 17 wires
MUST
be twisted
18 wire COM