1838-066-E-12-16
20
STOP!
If you are
OR
are going to use a computer with the 1838,
NO other programming at the System
Keypad is required.
All programming parameters beyond this point can be set in the Management software.
This software will show all the specific programming parameters that will exist in the memory of the 1838 after it has been
programmed. It can be easily recalled for future modification or re-programming.
Download
Access Plus Account Manager
software at: http://www.doorking.com/accessories/access-plus-software
The system keypad
DOES NOT
have the capability to show any of the programming that will exist
in the memory of the unit after being programmed. The only way to keep track of the specific
parameters that have been programmed into the unit for future reference when
NOT
using the
management software, is to physically write down all the information in a log (In back of manual).
2.3.3 Set the Gateway (Router) IP Address
(reboot required)
Factory setting is: 192.168.001.001
If the unit is connected directly to the computer with a crossover cable, then this address must be set to 000.000.000.000.
If the unit is connected to the computer through a router, then set this value to the router’s IP address. Valid value for any
of the three digit numbers is 000 to 255. (See section 1.9.2 for network configurations and addresses)
1.
Press
*
5 3 and enter the MASTER CODE.
[
*
5 3 _ _ _ _ (beep)]
2.
Enter the gateway (router) IP address. Use the
*
key to enter the “dot”.
[ _ _ _
*
(beep) _ _ _
*
(beep) _ _ _
*
(beep) _ _ _
*
(beep)]
3.
Press 0 # TOGETHER to end.
[0 # (beeeeeep)]
2.3.4 Set the Port Number
(reboot required)
Factory setting is: 01030
This must be the same port number that was programmed in the software. Valid values are 01024 to 65535.
All 5 digits must be entered in the field, for example: 1030 must be entered as 01030
1.
Press
*
5 6 and enter the MASTER CODE.
[
*
5 6 _ _ _ _ (beep)]
2.
Enter the port number, then press
*
.
[ _ _ _ _ _
*
(beep)]
3.
Press 0 # TOGETHER to end.
[0 # (beeeeeep)]
System
Keypad
0
8
9
7
5
6
4
2
3
1
System
Keypad
0
8
9
7
5
6
4
2
3
1
System
Keypad
0
8
9
7
5
6
4
2
3
1
2.3.5 Enable / Disable TCP / IP Support - System Reboot
Factory setting is: 0 (TCP / IP Disabled)
This programming sequence enables or disables the support for TCP / IP. It will also cause an automatic reboot of the unit
two seconds after the programming sequence is completed. For this reason, perform this step after all other network setup
programming sequences have been completed (sections 2.3.1 through 2.3.4) or whenever an individual network program-
ming step is performed.
Once the unit is connected, the green LED on the RJ-45 jack on the interface board should light indicating that a good wire
connection has been made (See illustration above). The LAN DOWN LED should go off after a few seconds if all previous
programming steps have been completed and programmed successfully.
1.
Press
*
5 0 and enter the MASTER CODE.
[
*
5
0 _ _ _ _ (beep)]
2.
Press 0
*
to disable TCP / IP
OR
press 1
*
to enable TCP / IP.
[ _
*
(beep)]
3.
The system will reboot automatically.
System
Keypad
0
8
9
7
5
6
4
2
3
1
SOFTW
ARE
INST
ALLE
D
SOFTW
AR
E
INST
ALLED
PC’s only, NOT for use with MACs
SOFTW
ARE
INST
ALLED