Before proceeding with any of the programming steps in this section,
install the Access Plus Management software on the
computer (PC ONLY) that will be used
for this purpose. Be sure that the computer has a network card installed, or a modem
installed in it (or connected to it) depending on which connection method will be used. Once the software is installed and the
unit is connected, refer to the software programming steps and help screen instructions to proceed with the programming steps
in this section. The system keypad may be used to program the computer’s network setup in this section but can be a little
tedious to use.
Be sure that SW1 is in the ON position (MODEM/TCP ENB) on the Access Plus Interface Board.
2.3 Programming the Network Setup for a Computer
Reboot Note:
If a programming step calls for a reboot, follow the programming steps in 2.3.5. If you are performing several
programming steps that call for a reboot, complete
ALL
of those steps first, then perform the reboot sequence in 2.3.5.
2.3.1 Set the 1838 IP Address
(reboot required)
Factory setting is: 192.168.001.030
This must be set to the same address that was programmed in the software. A valid value for any of the three digit fields in
this sequence is 000 to 255. (See section 1.9.2 for network configurations and addresses)
All 3 digits MUST be entered in each field between dots, for example: 192.168.1.30 must be entered as 192.168.001.030
1.
Press
*
5 1 and enter the MASTER CODE.
[
*
5 1 _ _ _ _ (beep)]
2.
Enter the IP address. Use the
*
key to enter the “dot”.
[ _ _ _
*
(beep) _ _ _
*
(beep) _ _ _
*
(beep) _ _ _
*
(beep)]
3.
Press 0 # TOGETHER to end.
[0 # (beeeeeep)]
Important Note:
The unit will prompt you with short tones
(beep)
when each programming step has been correctly keyed
in and with a long tone
(beeeeeep)
when all of the programming steps have been successfully completed in the sequence.
ON
ON
MODEM / TCP ENB
1972-010
SW1
SW2
1
2
3
4
5
6
7
8
J1
J4
RJ-45
Jack
(Cat5)
LAN DOWN
J1
J1
J1
J1
J1
J1
J1
1
1
LAN
CONNECTION
Cat5 Cable
DATA TRANSMIT
BAD DNS
TERMINATION
RS-485 RX
PHONE LINE
IN USE
System
Keypad
0
8
9
7
5
6
4
2
3
1
2.3.2 Sub-Net Mask
(reboot required)
Factory setting is: 255.255.255.000
All sub-net mask should be set to 255.255.255.000. This rarely needs to be changed, consult with your network expert
first. Valid values for any of the three digit numbers is 000 to 255.
1.
Press
*
5 2 and enter the MASTER CODE.
[
*
5 2 _ _ _ _ (beep)]
2.
Enter the sub-net mask number. Use the
*
key to enter the “dot”.
[ _ _ _
*
(beep) _ _ _
*
(beep) _ _ _
*
(beep) _ _ _
*
(beep)]
3.
Press 0 # TOGETHER to end.
[0 # (beeeeeep)]
System
Keypad
0
8
9
7
5
6
4
2
3
1