KR 805
Maintenance
11.12.08
9-6
9.2.1.1 Removing the grinding disc in the rotating flange, without screws
Procedure:
1.
Place a screwdriver (size 3) in the groove (1) at the grind-
ing disc (2).
2.
Rest the tip of the screwdriver on the facing edge and use
it to lever the grinding disc.
3.
Once the grinding disc has overcome the magnetic attrac-
tion, it can be remove manually.
Installation of the grinding disc is carried out in reverse order.
Fig. 9/6
HINT
Ensure that the grinding discs are positioned correctly during installation. Observe the position
of the driver!
HINT
Ensure that all the mating surfaces are absolutely clean before reassembly! Failure to do so will
result in inconsistent grinds.
9.2.1.2 Removing the grinding disc in the stationary flange, without screws
Procedure:
1.
Place a screwdriver in the groove (1) at the grinding disc
(2).
2.
Rest the tip of the screwdriver on the facing edge and use
it to lever the grinding disc.
3.
Once the grinding disc has overcome the magnetic attrac-
tion, it can be remove manually.
Installation of the grinding disc is carried out in reverse order.
Fig. 9/7
HINT
Ensure that grinding discs are positioned correctly during installation. Observe the position of
the driver!
HINT
Ensure that all the mating surfaces are absolutely clean before reassembly! Failure to do so will
result in inconsistent grinds.