Normally, the 

distyNotruf pro

 is subscribed as described in the previous chapter. The 

system has already been activated for subscription. The system administrator enters the new 
terminal device into the system.

Is the 

distyNotruf pro

 required to function in a specific facility? If yes, please follow the 

following instructions.

Subscription using PARK

RFPI/ PARI ( = Channel element / Base station ) is the default on which subscription is 
performed. This information can be found in ASCOM as System Administrator under DECT/ 
Radio/ RFPI 9014BC1008 ( <- Example! ).
The process is described as follows. This is performed with the help of the programming 
station ( Function ‘set PARK’, manual entry ).

c_31_9014_bc10_08

Set the RFPI of the channel element that is 
to be used for subscription.

( Please observe hexadecimal entry! )

The 

distyNotruf pro

 is subscribed as described above.

Subscription using SARI

In case of huge systems (integrated systems), affiliation is regulated through a SARI. This 
number will be disclosed to the system administrator and the new terminal device set-up in 
the system.
The system is activated for subscription; the administrator has disclosed the SARI used ( e.g. 
3111111111115 ) and the new terminal device set-up in the system. The SARI is entered in 
the device through the programming station ( PS, see chapter on “Requesting / Setting 
parameters and functions” ) ( 

Function 14 

). Subscription is now performed as described 

above.

Configuration

Some settings were made in the device during production, which shall be adapted to the 
respective purpose of application. For this purpose, see the section on 

“Requesting / Setting 

parameters”

 as well as 

“Configuration data”

It is necessary to configure the device accordingly depending on application. This is easiest 
when done with the aid of the programming adapter and programming software..
It is advisable to restart the 

distyNotruf pro

 after changing parameters.

Page 7 of 24

Summary of Contents for distyNotruf pro Ascom

Page 1: ...distyNotruf pro Ascom Operating Instructions...

Page 2: ...cs features 12 Emergency call default disabled 12 Announcement Call 12 Volumes 12 DECT Activity default disabled 13 Shock sensor Motion alarm default disabled 13 Announcement tone off ring tone defaul...

Page 3: ...ely as possible Do not leave the battery for a long time in a discharged state Keep the battery away from heat sources such as Heaters and open flames such as Candles Danger of explosion Do not use ch...

Page 4: ...r will then establish contact with the distyNotruf pro it reports back the current field strength of the base stations whose signals are most strongly received and if necessary additional information...

Page 5: ...DistyNotruf pro Ascom operating instructions Application Page 3 of 24...

Page 6: ...DistyNotruf pro Ascom operating instructions ASCOM Protocol DECT location service per SMS Page 4 of 24 ASCOM Beacon service...

Page 7: ...g plug Press the middle tab of the clip through the clamp and push it under the mounted spring bar Insert the second spring pin into the opposite end of the clip Move the clip to the approximate end p...

Page 8: ...is 0000 The distyNotruf pro is prepared through the following procedure The process functions only if the device is not subscribed See chapter on Factory setting The device is plugged into the CS Pre...

Page 9: ...pro is subscribed as described above Subscription using SARI In case of huge systems integrated systems affiliation is regulated through a SARI This number will be disclosed to the system administrat...

Page 10: ...sleeping mode no LED lights up DECT activity is halted Factory setting The following operating procedure is performed to reset to delivery status factory setting default which will work only when the...

Page 11: ...ory The following is a description of the handling With the power supply programming function PS the battery of the distyNotruf pro can either be charged or some settings modified through data transmi...

Page 12: ...the upper left button the APP starts into programming mode The lower line which shows the hint and or status gives the command to insert the distyNotruf pro After the PS has recognized the distyNotruf...

Page 13: ...the alarm button into the field Alarm number initiate the transmission by clicking the write button Now the LEDs again start blinking to indicate the ongoing communication At the end of transmission...

Page 14: ...speech connection This can be terminated only by pressing the button again If a distyNotruf pro is called which has no emergency number set then it stores the callers identity CLIP2 as emergency numbe...

Page 15: ...n alarm default disabled Performance characteristics serve the purpose of recognizing an accident on the part of the bearer e g fainting non usage of the device or touching of a secured object If the...

Page 16: ...240 seconds Alarm time of 4 minutes must be set through configuration If the device is not moved for a minimum of 4 minutes the respective SMS will be displayed at the OAPT interface The precise forma...

Page 17: ...switched on for at least 10 minutes and dispatches a SMS message Alarm Coordinates depending on configuration Patient receives visual and acoustic feedback Nurse is informed through her handset and ca...

Page 18: ...he distyNotruf pro for this purpose and the remote subscriber sends the respective sign After recognizing the desired setting in this case the introductory sign 9 a one minute countdown begins for the...

Page 19: ...n is made to any subscriber Then place the distyNotruf pro near the earpiece or speaker of the phone push the button on the distyNotruf pro and now select the above described combinations of numbers o...

Page 20: ...will be sent to our distyNotruf pro as a SMS PTP LQ Z 1 The device answers with a response message Locate Response Locate Response xml version 1 0 encoding UTF 8 OAP request id 9b8a01c3 version 4 0 H...

Page 21: ...ection xml User_data Data PTP PA Z 33 B 9014BC2009 50 D 3 Data Man Down xml User_data Data PTP PA Z 88 B 9014BC1008 51 D 2 Data Alarm button Personal Alarm user initiated xml User_data Data PTP PA Z 7...

Page 22: ...B 9014BC1008 63 H 1 C 002A 20 Data User_data It is allowed to send the protocol element H together with other SMS messages The range of the reference numbers 01 99 decimal notation The Beacon Id is tr...

Page 23: ...eted Flash rhythm every second Green LED as in 6 7 8 4 Charging DECT activity off Red LED flashes during charging and turns off when charging is completed Flash rhythm every second Green LED is off 5...

Page 24: ...ugging into the CS or removing from the CS If DECT activity is off DECT operation will be stopped during charging Moreover no SMS will be sent as described above The LEDs have a different meaning if o...

Page 25: ...lay 2 colors Microphone Lithium ion battery Capacity 450 mAh 3 7 V Charging time about 4 hrs for a complete charging cycle Operating temperature 10 C bis 40 C8 Storage temp 10 C bis 60 C Product appro...

Page 26: ...ting instructions distyNotruf pro Ascom http www disty eu All rights to changes reserved Any copy from this document needs a written permission disty communications gmbh Holzkoppelweg 14 D 24118 Kiel...

Reviews: