DECT Activity (default: disabled)
DECT remains switched off during charging. This can be modified through the configuration
data in such a way that the device remains switched on also during charging ( see
Function
24.2
)
Moreover, the event “Set in CS” or “Remove from CS” can be set to be transmitted as SMS
to the OAPT interface (format, see
SMS – messages
).
Note
: The alarm – functionality of the key is enabled 5 sec after inserting the device into
the charger!
Shock sensor/Motion alarm (default: disabled)
Performance characteristics serve the purpose of recognizing an accident on the part of the
bearer e.g. fainting, non-usage of the device or touching of a secured object.
If the acceleration values of the sensor fall short of a specific value ( = threshold ) for a
specific amount of time ( = time out ), alarm will be triggered ( Mode “Quiescence” / ‘man
down alarm’ )
Alarm is reported in the mode “active” ( / ‘moved after timeout’ ) if motion is detected after
a specific period in which no vibrations have been detected.
This is done in the form of an SMS message transmitted to the central OAPT interface as a
call to the preset emergency number.