MTG1000B Trunk Gateway User Manual
MTG1000B Trunk Gateway User Manual
47
Copyright @ 2011-2015 Dinstar
Outgoing Calls Registration
Whether to limit the number of the calls from PSTN to IP network.
The default value is ‘No’.
If ‘Yes’ is selected, then input the number of concurrent calls that are
allowed to go out. The range is 0 to 65535.
Incoming Calls Registration
Whether to limit the number of the calls from IP network to PSTN.
The default value is ‘No’.
If ‘Yes’ is selected, then input the number of concurrent calls that are
allowed to come in. The range is 0 to 65535.
Incoming Time Registration
The default setting is ‘Disabled’.
If ‘Enabled’ is selected, user can edit the start and stop time of a
prohibition period. During this period, all calls from IP network to PSTN
are prohibited. (Calls from PSTN to IP network are not limited)
Detect Trunk Status
Whether to detect the status of the SIP trunk. If ‘Yes’ is selected,
MTG1000B will send Heartbeat message to the peer device to confirm
whether the link status is OK.
Heartbeat Username
The name of the Heartbeat message
Enable SIP Trunk
Whether to enable the SIP trunk.
If ‘Yes’ is selected, the SIP trunk is available;
If ‘No’ is selected, the SIP Trunk is invalid.
Configuration procedures for Access Mode are as follows:
1.
Click the
Add
button to add a SIP trunk.
2.
Configure parameters on the following interface according to related explanations.
As it is Access mode, you should select
Yes
for the
Register to Remote
parameter, and enter the IP address of a
softswitch.