Procedures for adding SS7circuit that only involves an E1/T1 port:
Step 1: Click
Add
on the
SS7 CIC
interface.
Step 2: Select a trunk and an E1/T1 port. (Trunk 0 and Port 1 are taken as example in the following figure
As there
are 32 channels (from 0 to 31) for one E1/T1 port, so the value for
Count
is 32. When start E1/T1 port is
the same with end E1/T1 port, it means only one E1/T1 port is connected to the SS7 trunk.
Parameter
Explanation
Trunk No.
The No. of the SS7 trunk
Start E1/T1 Port No.
The No. of the start E1/T1 port
End E1/T1 Port No.
The No. of the end E1/T1 port
Start Channel
When the start E1/T1 port is also the end E1/T1 port, it’s required to set the start
channel, and the channels starting from the set channel to the No.31 channel of the
E1/T1 port will be used by the SS7 trunk.
Start CIC No.
CIC: Circuit Identification Code
The CIC No. of the start channel, which is generally 0, 32, 64, 96, 128, 160, 192,
224, 256, 288, 320, 352, 384, 416, 448…
Count