MTG1000B Trunk Gateway User Manual
MTG1000B Trunk Gateway User Manual
14
Copyright @ 2011-2015 Dinstar
4.1.2
Preparations for Login
Modify the IP address of the PC to make it at the same network segment with the IP address of FE0 port of
MTG1000B device. The format of PC IP is 192.168.1.XXX, since the default IP of FE0 port is 192.168.1.111.
Check the connectivity between the PC and the MTG1000B. Click
Start
Run
of PC and enter cmd
to execute
‘ping 192.168.1.111’ to check whether the IP address of the MTG1000B runs normally.
4.1.3
Log in Web Interface
Open a web browser and enter the IP address of FE0 of MTG1000B (the
default IP is
192.168.1.111). Then the
login GUI will be displayed.
Both the default username and password are admin.
It is suggested that you should modify the username and password for security consideration on the
Maintenance
Password Modification
interface.
Login GUI:
MTG1000B
Switch
Router
Internet
PC