MTG1000B Trunk Gateway User Manual
MTG1000B Trunk Gateway User Manual
29
Copyright @ 2011-2015 Dinstar
Parameter
Explanation
Trunk No.
The No. of the SS7 trunk
Link No.
Each SS7 trunk supports two links which share the loading equally. If one link
malfunctions, the other link will automatically bear all the loading until the faulty
link is restored.
Signaling Link Code
If the Link No. of the trunk cannot match with that of the peer device, the SS7
trunk will be linked to the peer device according to signaling link code.
E1/T1 Port No.
The No. of E1/T1 port linked to the SS7 trunk
Channel No.
The No. of the channel under which signal is transmitted. Default value is 16.
Caller Type
The type of the caller number. Options include ‘Not Configured’, ‘Subscriber’,
‘International” and “National’.
Callee Type
The type of the called number. Options include ‘Not Configured’, ‘Subscriber’,
‘International” and ‘National’.
OrgCallee Type
The type of the original called number in case of number manipulation. Options
include ‘Not Configured’, ‘Subscriber’, ‘International’ and ‘National’.
Numbering Plan
Options include ‘ISDN’, ‘Data’, ‘Telex’ and ‘Private’.
Calling Presentation
If ‘Allowed’ is selected, the calling number will be presented.
If ‘Restricted’ is selected, the calling number will not be presented.
If ‘Not Config’ is selected, the parameter does not work.
Screening Indicator
Options include “User Provided” and “Network Provided”.
Calling Stop Sending
‘Stop Sending’ is an end mark. If ‘Yes’
is selected for ‘Calling Stop Sending’, it
means there will be an end mark following the calling number.
Called Stop Sending
‘Stop Sending’ is an end mark. If ‘Yes’
is selected for ‘Called Stop Sending’, it
means there will be an end mark following the called number.
4.7.4
SS7 CIC
On the
SS7 Config
SS7 CIC
interface, click the
Add
button, and you will see the following interface. You can
determine which channels will be used by an SS7 trunk on the interface.