![Digital Security Controls WLS9000 Manual Download Page 51](http://html1.mh-extra.com/html/digital-security-controls/wls9000/wls9000_manual_2499479051.webp)
Digital Security Controls Ltd.
51
Private and Confidential
Installation Manual
DATE : 09/30/97
DRAFT
[017] FIFTH SYSTEM OPTION CODE
Default
Option ON
Option OFF
OFF I___I
Option 1
WLSKey Does Not Use Access Codes
WLSKey Uses Access Codes
ON
I___I
Option 2
Verbal Chime is Enabled
Verbal Chime is Disabled (Beeps only)
ON
I___I
Option 3
Verbal Alarm is Enabled
Verbal Alarm is Disabled (Siren Only)
ON
I___I
Option 4
Local Annunciation Enabled
Local Annunciation Disabled
xviii
OFF
I___I
Option 5
Remote Annunciation Enabled
Remote Annunciation Disabled
OFF I___I
Option 6
For Future Use
OFF I___I
Option 7
For Future Use
OFF I___I
Option 8
Squawk on Away Arming/Disarming Only
Bell Squawk on all Arming/Disarming
ADVANCED SYSTEM PROGRAMMING
ZONE ATTRIBUTE DEFAULTS
Zone Type
On
Off
Opt. 1
Audible
Silent
Opt. 2
Steady
Pulsed
Opt. 3
Chime
No
Opt. 4
Bypass
No
Opt. 5
Force
No
Opt. 6
Swing.
No
Opt 7
Tx Del.
No
Opt. 8
Wireless
No
00 Null Zone
Off
Off
Off
Off
Off
Off
Off
On
01 Delay 1
On
On
On
On
Off
On
Off
On
02 Delay 2
On
On
On
On
Off
On
Off
On
03 Instant
On
On
On
On
Off
On
Off
On
04 Interior
On
On
Off
On
Off
On
Off
On
05 Interior, Stay-Away
On
On
Off
On
On
On
Off
On
06 Delay, Stay-Away
On
On
Off
On
On
On
Off
On
07-08 Not Used
xix
Off
Off
Off
Off
Off
Off
Off
Off
09 24 Hour Supervisory
Off
On
Off
Off
On
Off
Off
On
10 24 Hr Superv. Buzzer
Off
On
Off
On
Off
Off
Off
On
11 24 Hour Burglary
On
On
Off
On
Off
Off
Off
On
12 24 Hour Holdup
Off
On
Off
Off
Off
Off
Off
On
13 24 Hour Gas
On
Off
Off
Off
Off
Off
Off
On
14 24 Hour Heat
On
Off
Off
Off
Off
Off
Off
On
15 24 Hour Medical
On
On
Off
Off
Off
Off
Off
On
16 24 Hour Panic
On
On
Off
Off
Off
Off
Off
On
17 24 Hour Emergency
On
On
Off
Off
Off
Off
Off
On
18 24 Hour Sprinkler
On
On
Off
Off
Off
Off
Off
On
19 24 Hour Water
On
On
Off
Off
Off
Off
Off
On
20 24 Hour Freeze
On
On
Off
Off
Off
Off
Off
On
21 24 Hour Latching Tamper
On
On
Off
Off
Off
Off
Off
On
22 Momentary Keyswitch
Off
Off
Off
Off
On
Off
Off
On
23 Maintained Keyswitch
Off
Off
Off
Off
On
Off
Off
On
24 Not Used
Off
Off
Off
Off
Off
Off
Off
On
25 Interior Delay
On
On
Off
On
Off
On
Off
On
87 Delayed 24Hr Fire (Wireless)
On
Off
Off
Off
Off
Off
Off
On
88 Standard 24Hr Fire (Wireless)
On
Off
Off
Off
Off
Off
Off
On