Digital Security Controls Ltd.
35
Private and Confidential
Installation Manual
DATE : 09/30/97
DRAFT
The user can use the [*][6][Master Code][6] Command to enable a 6 hour window in which the panel
will answer calls for downloading if a successful Double Call routine is detected. If this option is
enabled, the window is open upon power up. The window is on for the full 6 hours if enabled.
OFF = User Can Not Enable DLS Window.
The user can not enable a window for DLS calls.
Note: Options 1 and 2 are not related. One does not need to be enabled for the other to
perform its function.
[3] Call-Back Options
ON = Call-Back Enabled.
When the system answers the downloading computer’s call, both the computer and the WLS9000
will hang up. The panel will then call the Downloading Telephone Number and connect with the
computer at that number. If more than one downloading computer is to be used, this function should
be disabled.
OFF = Call-Back Disabled.
The downloading computer will have immediate access to the WLS9000 once it is identified as a
valid system.
[5] Auto Event Buffer Upload
ON = Auto Event Buffer Upload Enabled.
After the panel has communicated the “Event Buffer 75% Full” event to central station, the panel
will call the Downloading Computer’s telephone number. DLS software will then perform an event
buffer upload upon successful connection.
OFF = Auto Event Buffer Upload Disabled.
After the panel has communicated the “Event Buffer 75% Full” event to central station, the panel
will
not
call the Downloading Computer’s telephone number.
[6]-[8] For Future Use
[402] Downloading Computer’s Telephone Number
This telephone number is 32 digits in length.
[403] Downloading Access Code
This 4-digit Hexadecimal code allows the panel to confirm that it is communicating with a valid downloading
computer.
[404] Panel Identification Code
This 4-digit Hexadecimal code allows the downloading computer to confirm the identity of the control panel.
[405] Double-Call Timer
This timer sets the amount of time that can be taken between calls when using Double Call to contact the WLS9000.
Valid entries are 001 to 255 (seconds)
[406] Number of Rings to Answer On
The value in this section determines how many rings that the WLS9000 will automatically pick up on in order to
establish a DLS connection. Default value is 000 rings. Valid entries are [000]-[020].
NOTE: If both Section [401] Option 1 and Section [406] are enabled, either one will work depending on
how the installer calls the premises.