![Digital Security Controls WLS9000 Manual Download Page 23](http://html1.mh-extra.com/html/digital-security-controls/wls9000/wls9000_manual_2499479023.webp)
Digital Security Controls Ltd.
23
Private and Confidential
Installation Manual
DATE : 09/30/97
DRAFT
be supervised via the panel’s EOL supervision, and will operate according to the zone type programmed. If a zone is
disabled, it will not be supervised and all activity on the zone will be ignored by the panel.
8.2.9 Telephone Numbers
[301] First Telephone Number
[302] Second Telephone Number
[303] Third Telephone Number
All telephone numbers are 32 digits in length.
Hexadecimal digits may be programmed in the telephone number to perform certain functions.
Enter [*2*] - HEX B to dial “*”
Enter [*3*] - HEX C to dial “#”
Enter [*4*] - HEX D for an additional dial tone search, as is required for PBX telephone systems.
Enter [*5*] - HEX E to insert a 2 Second Pause in the telephone number.
Notes: -There is a static delay of 2 seconds before any additional dialtone search in a phone number.
-HEX A is not used; HEX F represents the end of the Phone Number (everything after F is ignored)
-In order to comply with European PTT specification requirements, the panel will not attempt to
communicate, if no phone number is programmed. This applies to Phone Numbers 1 and 2.
[310] Telephone Number 1/3 Account Code
This is the Account Code used by the panel when communicating via Phone Numbers 1 and 3.
[311] Telephone Number 2 Account Code
This is the Account Code used by the panel when communicating via Phone Number 2.
Note: Both Account Codes are 4 digits in length. Valid entries are 0000-FFFE.
8.2.10 Reporting Codes
Zone Alarms & Alarm Restorals
These reporting codes are used by the communicator to transmit zone alarms and restorals for zones 1
to 32.
These reporting codes are sent to the Alarm & Restoral call direction group.
Duress Alarm
This reporting code will be transmitted to the monitoring station whenever either Duress code is used to
perform any function on the system.
This reporting code is sent to the Alarm & Restoral call direction group.
Opening After Alarm
If programmed, this reporting code will be transmitted to the monitoring station on Opening if an alarm
occurred during the previous armed period.
This reporting code is sent to the Alarm & Restoral call direction group of the System.
Recent Closing