Digital Security Controls Ltd.
33
Private and Confidential
Installation Manual
DATE : 09/30/97
DRAFT
[7] Not Used
[8] Delinquency Options
ON = Delinquency Follows Zone Activity (Activity Delinquency).
This feature assists in the monitoring of the elderly and the handicapped. If there is no zone activity
on the system, the Delinquency Transmission Delay timer in Section [370] will begin counting in
hours
. When the counter reaches the programmed time, the panel will communicate the
Delinquency Code to the central station, if programmed. If there is zone activity present on the
system at any time, the counter will be reset. If this option is used, the Closing Delinquency option is
not available.
Notes: This code will not be transmitted for panels that are “Away” armed.
Activity on Bypassed zones does not affect this timer.
This timer is also reset upon arming.
OFF = Delinquency Follows Arming (Closing Delinquency).
This reporting code is sent whenever the programmed number of days for Delinquency has
expired without the panel being Armed. The timer for this feature is programmed in Section [370].
This value programmed in this section determines the number of days the panel counts when not
being armed before sending the Delinquency reporting code to the central station. Once this code is
sent, the timer will not be started again until the panel has been armed. Each day programmed in
the counter represents one day PLUS the time it takes for the panel to reach midnight. This feature
may disabled by programming 000 in Section [370].
[381] Second Communicator Options Code
[1] Opening After Alarm Keypad Ringback Options
ON = Opening After Alarm Keypad Ringback Enabled.
When the Opening After Alarm reporting code is successfully transmitted to a programmed
telephone number, the keypad will sound a series of 8 beeps to confirm to the end user that the
Opening After Alarm Code was sent and received. This Ringback will occur for each Opening After
Alarm code successfully reported.
OFF = Opening After Alarm Keypad Ringback Disabled
[2] Opening After Alarm Bell Ringback Options
ON = Opening After Alarm Bell Ringback Enabled.
When the Opening After Alarm reporting code is successfully transmitted to a programmed
telephone number, the Bell will sound a series of 8 squawks to confirm to the end user that the
Opening After Alarm Code was sent and received. This Ringback will occur for each Opening After
Alarm code successfully transmitted.
OFF = Opening After Alarm Bell Ringback Disabled
[3] SIA Reporting Code Options
This option is for use with the SIA communication format.). If 00 is programmed in the reporting code
section, the event will not be communicated.
ON = SIA Sends Programmed Rep. Codes.
When this option is ON and there is a valid reporting code programmed in the reporting code
section, the programmed reporting code will be transmitted.
If FF is programmed as a reporting code, the event will not be communicated.
OFF = SIA Sends Automatic Rep. Codes.
When this option is OFF and there is a valid reporting code (01-FE) or FF programmed in the
reporting code section, the panel will transmit an automatic reporting code for SIA only. This would
be used when automatic reporting codes are required but there is a requirement for a different
reporting code (ie Pager Format, etc).
Reporting Code Entry
Option ON
Option OFF