DATE : 09/30/97
DRAFT
[4] Bell Squawk On Entry Options
ON = Bell Squawk On Entry Delay.
The Bell output will pulse with the same timing as the keypad buzzer during the Entry Delay time.
The bell will sound 3 squawks per second for the final 10 seconds if Option 6 in this section is
enabled.
OFF = No Bell Squawk On Entry Delay.
[5] Bell Squawk on Trouble Options
ON = Bell Squawks on Trouble.
Whenever there is a Trouble condition enunciated on the system keypads, the Bell will squawk 2
times every 10 seconds (as per the keypad buzzer). The Bell will be silenced when the keypad
beeps are silenced (any key pressed on keypad).
OFF = No Bell Squawks on Trouble.
[6] Audible Exit Beeps
ON = Audible Exit With Urgency.
The keypad will sound a pulsing tone (once per second) during the Exit Delay. For the last 10
seconds of the Exit Delay, the keypad and bell / siren (if enabled) will sound a different tone (3 tones
per second) to warn that the Exit Delay is about to expire.
OFF = Silent Exit Delay.
The keypad will not sound during the Exit Delay.
[7] Exit Delay Termination Options
ON = Exit Delay Termination Enabled.
The Exit Delay will be terminated once a Delay 1 Zone for the entry/exit door or area is restored. All
audible options associated with the exit delay will be silenced when the Exit Delay is terminated.
Force-Armable Delay 1 type zones will also terminate the exit delay.
OFF = Exit Delay Termination Disabled.
The Exit Delay timer will continue to count even after the Delay Zone for the entry/exit door or area is
restored. All audible options associated with the Exit Delay will function until the time programmed
for the Exit Delay has elapsed.
[8] Fire Bell Timeout Options
ON = Fire Bell is Continuous.
For all Fire type alarms, the Bell output will sound until an access code is entered to silence the
alarm or disarm the system regardless of the time programmed for Bell Timeout in Section [005].
OFF = Fire Bell Follows Timeout.
For all Fire type alarms, the Bell output will sound for the length of Bell timeout or until an access
code is entered.
[015] Third System Options Code
[1] [F] Key Options
ON = [F] Key Enabled.
Pressing and holding the [F] keys for 2 seconds will generate a Fire alarm. The keypad will sound a
set of 3 beeps to acknowledge the valid alarm and the bell or siren will sound with a pulsing tone for
the length of Bell time-out. An alarm reporting code (if programmed) will be transmitted.
OFF = [F] Key Disabled.
The [F] key will not sound or report an alarm when pressed.
[2] [P] Key Annunciation Options
ON = [P] Key Audible.
When a valid [P] key alarm is generated, the Keypad buzzer will sound a series
of 3 beeps to acknowledge the alarm and the bell or siren will sound for the length of Bell timeout.
OFF = [P] Key Silent.