E—4
Fault Finding and Maintenance
MAINTENANCE
LBV00056; Revision C - 01/03/03
Lamp Replacement
To remove the existing lamp follow the procedure below:-
1. Turn off the existing lamp using the LAMP OFF button on the remote control
unit and to allow the cooling fan to run for 10 minutes.
2. Disconnect the projector from the mains supply and wait 5 minutes for the
projector to cool down.
3. Undo the six screws on the right hand side cover using a flat-head screw driver
and remove cover.
4. Unscrew the three retaining screws securing the lamp in position (see diagram
opposite).
5. Using the handle provided on the lamp housing slide out the lamp and remove
to a safe location.
Maintenance
Lamp Housing
Summary of Contents for lightning series