6–16
Table 6–1. LCD Message Troubleshooting Table (continued)
Displayed
Message
Operator
Can
Correct?
Explanation
Solution
PLAT INV STATE*
No
Fatal firmware error on
CMX controller board.
Contact your Digital
Customer Service Engineer.
1
POWER SUPPLY HOT
No
Circuits are overheating
on the power supply
board.
Contact your Digital
Customer Service Engineer.
1
PRINTER HOT
No
Controller board sensors
report high temperatures
on the board.
Contact your Digital
Customer Service Engineer.
1
PROTECTED INSTR*
No
Fatal firmware error on
CMX controller board.
Contact your Digital
Customer Service Engineer.
1
PWR SUPP VOLT *
No
Power supply failed.
Replace power supply board.
RIB INVLD CMD*
No
Fatal firmware error on
CMX controller board.
Contact your Digital
Customer Service Engineer.
1
RIB INVLD STATE*
No
Fatal firmware error on
CMX controller board.
Contact your Digital
Customer Service Engineer.
1
RIBBON DRIVE
No
CMX controller does not
detect ribbon drive motor.
Contact your Digital
Customer Service Engineer.
1
SECURITY
VIOLATION
No
Security code of PAL on
controller board does not
match code of firmware
on the CMX controller
board.
Contact your Digital
Customer Service Engineer.
1
SHUTL INV CMD*
No
Fatal firmware error on
CMX controller board.
Contact your Digital
Customer Service Engineer.
1
SHUTL INV PARM*
No
Fatal firmware error on
CMX controller board.
Contact your Digital
Customer Service Engineer.
1
1
Before contacting a Digital Customer Service Engineer, power off the printer, wait 15 seconds, then
power it back on and rerun your print job. If the message reappears, press CLEAR then ONLINE. If the
fault message still displays, then contact the Customer Service Engineer.