General Specificatio ns
Maximum v oltage bet ween any Terminals and Grounding: 1000V.
Fused Protection f or
mA
Input Terminal: 0.315A, 250V f ast ty pe, Ø 5 x 20 mm.
Fused Protection f or
10A
or
20A
Input Terminal: Un-f used.
Range: Manual ranging
Maximum display : 1999.
Measurement Speed: Updat es 2~3 times/sec ond
Tem perature
: Operating: 0°C~40°C (32°F~104°F).
: Storage: –10°C~+50°C (14°F ~122°F).
Relativ e Humidity
: <75%@ 0°C ~30°C; <50%@ 31°C ~40°C.
Altitude
: Operating 2000m; Storage 10000m.
Battery Type
: 9V NEDA1604 or 6F22 or 006P.
Battery Def iciency
: Display “ ”
Data Holding
: Display “
H
”
Negativ e reading
: Display “
”
Ov erloading
: Display
“1”
.
Dimensions
: 172mm x 83mm x 38mm
Weight
: Approx. 310g (battery included).
Saf ety/Compliances
:IEC61010 CAT.I 1000V, CAT.II 600V ov ervoltage and double insulation
standard.
Certificate
: CE