Operational Requirements
Temperature and Ventilation
D-Command should be installed and operated in a cli-
mate-controlled environment, away from heat sources, and
with adequate ventilation. D-Command should be operated at
an ambient temperature that does not exceed 100 degrees F
(35 degrees C).
The back panel and the front half of the bottom panel of each
unit should be exposed to ambient air. Blocking or partially
blocking the back panel or bottom panel of a D-Command
unit may cause the unit to malfunction and may void your
warranty.
Water and Moisture
D-Command units should be operated away from sources of
moisture or humidity and should be protected from liquid
spills.
Cleaning and Maintenance
If you need to clean the D-Command top surface, apply a
non-chlorine bleach based cleaning solution to a cloth or
paper towel, then carefully wipe the surface. Do not use
abrasives, cleaning solutions with chlorine bleach, or spray
cleaners.
Connection Requirements
Power Connections
Each unit (D-Command Main Unit, Fader Module, and
XMON Monitor Interface) requires its own power connection.
Make sure your power source is correctly rated for the number
of units you are connecting. A surge protected power source
(not included) is highly recommended.
Ethernet Connections
Each D-Command unit communicates with Pro Tools using
Ethernet. A single Main Unit can be connected to the host
computer without an Ethernet hub. To connect multiple
D-Command units to the host computer, an Ethernet hub
(not included) is required.
Audio Connections
All external analog audio inputs and outputs for control room
monitoring and studio communication are connected to the
XMON interface. D-Command connects to the XMON inter-
face with a single 15-pin cable (included). All analog inputs
and outputs on the XMON use DB-25 connectors.
Audio Cables for D-Command Monitoring
Digidesign offers a range of DigiSnake cabling options for con-
necting Digidesign interfaces and external sources to the
XMON monitoring system. For details, visit the Digidesign
website (www.digidesign.com).
System Requirements
D-Command requires the following system components:
• Pro Tools|HD® system (which includes at least one
Pro Tools|HD audio interface)
An expanded Pro Tools|HD system is required for higher track
counts.
For complete system requirements, visit the Digidesign
website (www.digidesign.com).
Compatibility Information
Digidesign can only assure compatibility and provide support
for hardware and software it has tested and approved.
For a list of Digidesign-qualified computers, operating sys-
tems, and third-party devices, visit the Digidesign website
(www.digidesign.com).
Summary of Contents for D-Command
Page 1: ...D Command Version 7 3 ...
Page 4: ......
Page 7: ...Part I Introduction ...
Page 8: ......
Page 19: ...Part II Installation ...
Page 20: ......
Page 35: ...Part III Reference ...
Page 36: ......
Page 72: ...D Command Guide 66 ...
Page 90: ...D Command Guide 84 ...
Page 124: ...D Command Guide 118 ...
Page 128: ...D Command Guide 122 ...
Page 134: ...D Command Guide 128 ...
Page 135: ......