AT commands
Serial interfacing commands
XBee/XBee-PRO® S2C ZigBee® RF Module
237
RO (Packetization Timeout)
Set or read the number of character times of inter-character silence required before transmission
begins when operating in Transparent mode.
Set
RO
to 0 to transmit characters as they arrive instead of buffering them into one RF packet. The
RO
command is only supported when operating in Transparent mode.
Parameter range
0 - 0xFF (x character times)
Default
3
Sets or displays the DIO7/CTS pin configuration (TH pin 12/SMT pin 25).
Parameter range
0, 1, 3 - 7
Parameter
Description
0
Unmonitored digital input
1
CTS flow control
3
Digital input
4
Digital output, low
5
Digital output, high
6
RS-485 Tx enable, low Tx
7
RS-485 Tx enable high, high Tx
Default
0x1
D6 (DIO6/RTS)
Sets or displays the DIO6/RTS pin configuration (TH pin 16/SMT pin 29).
Parameter range
0, 1, 3 - 5
Parameter
Description
0
Unmonitored digital input
1
RTS flow control
3
Digital input