
API Operation
Send Public Profile Commands with the API
XBee/XBee-PRO® S2C ZigBee® RF Module
216
Frame Fields
Offset Description
Device class
30
This bit encoded field represents the Device Class
associated with the Load Control Event. A bit value of
0x0014 enables smart appliances and water heaters.
Note
The 2-byte bit field value is sent in little endian
byte order.
31
Utility
enrollment
group
32
Used to identify sub-groups of devices in the device-
class. 0x00 addresses all groups.
Start time
33
34
35
36
Duration in
minutes
37
This 2-byte value must be sent in little endian byte
order.
38
Criticality
level
39
Indicates the criticality level of the event. In this
example, the level is “voluntary”.
Cooling
temperature
40
Requested offset to apply to the normal cooling set
point.
A value of 0xFF indicates the temperature offset
value is not used.
Heating
temperature
offset
41
Requested offset to apply to the normal heating set
point.
A value of 0xFF indicates the temperature offset
value is not used.
Cooling
temperature
set point
42
Requested cooling set point in 0.01 degrees Celsius.
A value of 0x8000 means the set point field is not
used in this event.
Note
The 0x80000 is sent in little endian byte order.
43