API Operation
Frame descriptions
XBee/XBee-PRO® S2C ZigBee® RF Module
201
Over-the-Air Firmware Update Status - 0xA0
Description
The Over-the-Air Firmware Update Status frame provides an indication of the status of a firmware
update transmission attempt. A query command (0x01 0x51) sent to a target with a 64-bit address of
0x0013A200 40522BAA through an updater with 64-bit address 0x0013A200403E0750 and 16-bit
address 0x0000, generates the following expected response.
Format
The following table provides the contents of the frame. For details on frame structure, see
Frame data fields
Offset Description
Frame type
3
0xA0
64-bit Source
(remote) address
4-11
MSB first, LSB last. The address of the remote radio returning this
response.
16-bit destination
address
12-13
The 16-bit address of the updater device.
Receive options
14
0x01 - Packet Acknowledged.
0x02 - Packet was a broadcast.
Bootloader message
type
15
0x06 - ACK
0x15 - NACK
0x40 - No Mac ACK
0x51 - Query (received if the bootloader is not active on the
target)
0x52 - Query Response
Block number
16
Block number used in the update request. Set to 0 if not
applicable.
64-bit target address
17-n
The 64-bit Address of remote device that is being updated (target)
Example
If a query request returns a 0x15 (NACK) status, the target is likely waiting for a firmware update
image. If no messages are sent to it for about 75 seconds, the target will timeout and accept new
query messages.
If a query returns a 0x51 (QUERY) status, then the target's bootloader is not active and will not
respond to query messages.
Frame data fields
Offset
Example
Start delimiter
0
0x7E
Length
MSB 1
0x00