Modem Status frame - 0x8A
Description
Devices send the status messages in this frame in response to specific conditions.
Format
The following table provides the contents of the frame. For details on frame structure, see
Frame data fields
Offset
Description
Frame type
3
0x8A
Status
4
0 = Hardware reset
1 = Watchdog timer reset
2 =Joined network (routers and end devices)
3 = Disassociated
6 = Coordinator started
7 = Network security key was updated
0x0D = Voltage supply limit exceeded (PRO only)
0x11 = Modem configuration changed while join in progress
0x80+ = Ember ZigBee stack error
Example
When a device powers up, it returns the following API frame.
Frame data fields
Offset
Example
Start delimiter
0
0x7E
Length
MSB 1
0x00
LSB 2
LSB 2
0x02
Frame type
3
0x8A
Status
4
0x06
Checksum
5