API Operation
Frame descriptions
XBee/XBee-PRO® S2C ZigBee® RF Module
184
Frame data
fields
Offset Description
Analog
sample
21-22
If the sample set includes any analog I/O lines (Analog channel mask > 0),
each enabled analog input returns a 2-byte value indicating the A/D
measurement of that input. Analog samples are ordered sequentially from
ADO/DIO0 to AD3/DIO3.
Example
In the following example, the device receives an I/O sample with an analog and digital I/O from a
remove device with a 64-bit serial number of 0x0013A20040522BAA and a 16-bit address of 0x7D84.
If you enable pin AD1/DIO1 as an analog input, enable AD2/DIO2 and DIO4 as digital inputs (currently
high), and enable AD3/DIO3 as a digital output (low) the I/O sample is shown in the API example in the
following table.
Frame fields
Offset
Example
Start delimiter
0
0x7E
Length
MSB 1
0x00
LSB 2
0x14
Frame type
3
0x92
64-bit source address
MSB 4
0x00
5
0x13
6
0xA2
7
0x00
8
0x40
9
0x52
10
0x2B
LSB 11
0xAA
16-bit source network address
MSB 12
0x7D
LSB 13
0x84
Receive options
14
0x01
Number of samples
15
0x01
Digital channel mask
16
0x00
17
0x1C
Analog channel mask
18
0x02