API Operation
Frame descriptions
XBee/XBee-PRO® S2C ZigBee® RF Module
190
Example
If you press the commissioning pushbutton on a remote device with 64-bit address
0x0013A200407402AC and a default
NI
string sends a Node Identification, all devices on the network
receive the following node identification indicator:
A remote device with 64-bit address 0x0013A200407402AC and a default
NI
string sends a Node
Identification, all devices on the network receive the following node identification indicator:
If you press the commissioning button on a remote router device with 64-bit address 0x0013A200
40522BAA, 16-bit address 0x7D84, and default
NI
string, devices on the network receive the node
identification indicator.
Frame data fields
Offset
Example
Start delimiter
0
0x7E
Length
MSB 1
0x00
LSB 2
0x20
Frame type
3
0x95
64-bit source address
MSB 4
0x00
5
0x13
6
0xA2
7
0x00
8
0x40
9
0x52
10
0x2B
LSB 11
0xAA
16-bit source
network address
MSB 12
0x7D
LSB 13
0x84
Receive options
14
0x02
Source 16-bit address
15
0x7D
16