AT commands
Serial interfacing commands
XBee/XBee-PRO® S2C ZigBee® RF Module
234
value is measured in -dBm. For example, if
DB
returns 0x50, then the RSSI of the last packet received
was -80 dBm.
Parameter range
0 - 0xFF
Observed ranges:
XBee-PRO - 0x1A - 0x58
XBee- 0x 1A - 0x5C
Default
N/A
PP (Peak Power)
Reads the dBm output when you select maximum power (PL4).
Parameter range
0x0 - 0x12
Default
[read-only]
Serial interfacing commands
The following AT commands are serial interfacing commands.
API Enable
Enables API Mode. The device ignores this command when using SPI. API mode 1 is always used.
Parameter range
0 - 2
Parameter
Description
0
API disabled (operate in Transparent mode)
1
API enabled
2
API enabled (with escaped control characters)
Default
0
AO (API Options)
Configure the options for API. The current options select the type of receive API frame to send out the
UART for received RF data packets.