5
335
118
335
STOP
SQUARE
DICTATOR Technik GmbH · +49 (0)821 246730 · [email protected] · www.dictator.de · 22.06.22
Technical manual: SQUARE 940-2
1.1 DIMENSIONS OF THE CASING
Dimensions in mm
Marked holes for 10
screw cable inlets M20
1.2 INSTALLATION / ELECTRICAL CONNECTION OF DOOR
OPERATORS
The installation of the control system is very easy, as the electronics are fixed on a board that
can be removed completely from the casing. The lid of the casing can also be taken off, as
the flat cable connection to the display in the lid just has to be unplugged. The now very light
casing can be fixed to the wall, without the danger of damaging the electronics by chance
with e.g. a screw driver.
The control system should be placed not farther than 30 m from the door operator.
Door operator, operating elements and safety equipments are connected to the removable bind-
ers. The blocks of binders are coded and therefore cannot be plugged into a wrong position.
The SQUARE 940-2 control system permits to adjust the DICTATOR DICTAMAT door operator
exactly to each door. This is a vital condition for the safety at powered doors.