32
»
Technical manual: SQUARE 940-2
DICTATOR Technik GmbH · +49 (0)821 246730 · [email protected] · www.dictator.de · 22.06.22
5.8 SYSTEM STATUS
System status
Submenus
Description
Overview
Here you can see the status of the light barriers, the safety
edges and the current position.
Photocells
Displays the analog value of the received signal strength
and gives a graphical representation of the current status
of the light barrier. Set the maximum value when aligning
the photoelectric sensor.
Position
Displays the number of internal door positions. If an
incremental encoder is used, additional information on the
reference status is displayed.
Reference
Displays information about the current reference status,
whether the position was found or not, connection errors,
and if the door is above or below the reference switch.
Safety Edge
Displays the current status of the safety edges.
Inputs
Quick overview of the control panel inputs. The box is
checked when the input is active.
Outputs
Quick overview of the control panel outputs. The box is
checked when the output is active.
Fault Log
Log displays the last 10 error messages. It displays the
error code and the door operating cycle in which it
occurred.
Input Log
Log shows the last 10 activated inputs. It shows the input
and the door operating cycle. Press UP + DOWN for 3
sec to clear.