50
Technical manual: SQUARE 940-2
DICTATOR Technik GmbH · +49 (0)821 246730 · [email protected] · www.dictator.de · 22.06.22
6.3 QUICK SETUP
Step
Indication
Action
1
Check direction
of motor rotation:
Use the UP button to move the door in the “OPEN“
direction. Check that the door is moving in
the “OPEN“ direction.
The door stops automatically. Release the button and
when the direction is OK, press UP. If wrong, press
DOWN. The controller automatically changes the
direction of motor rotation.
2
«fully open»
Position:
Use the UP key to move the door to the fully open
position. The respective position can be corrected at any
time with the DOWN key.
Save the position by pressing MENU/ENTER.
3
«fully closed»
Position:
Now move the door to the fully closed position with the
DOWN key. The respective position can be corrected at
any time with the UP key.
Save the position by pressing MENU/ENTER.
Incremental rotary encoder: If you are using an
incremental encoder, please perform a reference run by
pressing MENU/ENTER to calculate the position values
to be stored.
4
Ready:
Quick Setup is ready. The calculated values are now saved.
The operating mode is set to Auto.
If an error occurs, the error code E17 is displayed. The limits are
then reset. In this case, you must start again from step 1.
5
Completion
commissioning:
The display from step 4 changes to “Find Ref“ after approx. 3
seconds. To initialize the normal operating mode, the reference
point must now be approached again. This is now done via the
connected command generators in deadman --> If the mechanical
stop OPEN was selected as reference, an OPEN command must
be issued. If the mechanical stop CLOSED has been selected, a
CLOSE command must be issued.
»