5.12.2 Outputs
Output
Description
Relay 1
Relay outputs max.
1 A @ 24 VDC
0.5 A @ 120 VAC
Only ohmic loads
Relay 2
Relay 3
Relay 4
Power Relay
Power relay output max. 5 A @ 240 VAC.
NPN 1
Open Collector max. 30 VDC, 50 mA
non-inductive
NPN 2
Output functions
Description
No Function
Relay not active
Door Moving
Active if the output frequency is > 0.5 Hz.
Door Idle
Active if the output frequency is < 0.5 Hz.
Door Open
Active when the door is above the fully open position.
Door Closed
Active when the door is under the fully closed position.
Door Not Closed
Active when the door is above the fully closed position.
Open Partial
Active when the door is open at “Part Open 1“.
Door Opening
Active while the door opens.
Door Closing
Active while the door closes.
Delay To Close
Active while the closing timer delay is > 0.
Delay To Open
Active while the opening timer delay is > 0.
Auto Close Active
Active while Auto Close timer is > 0.
System Error
Active if an error message exists.
Pre-Warn
Active when the warning time is > Auto Close timer.
Open Alarm
Active if the door is open longer than the Open Alarm timer.
Service Counter
The operating counter has exceeded the value of the service counter.
Brake After Run
Active at half timeout of overrun pressure - for mechanical brake (for sliding
doors with seals).
Open Light
Function optimized for “door opens“ light signal.
Closed Light
Function optimized for “door closes“ light signal.
Part Open Light
Function optimized for door “Part Open 1“ light signal.
Mechanical Brake
Active when mechanical brake is applied.
System OK
Function optimised for “door opens“ light signal.