User parameters (profile «Std. 50 Hz»)
Revolutions: 1330 r/min
V/F open: 50 Hz
V/F close: 50 Hz
Boost open: 15 %
Boost close: 15 %
High boost: 0
Switch Frequenz open: 8,0 kHz
Switch Frequenz close: 8,0 kHz
Positions Tol: 2 pos.
Relay Tol: 10 pos.
DC Brake Cur: 0 %
DC Brake Time: 0,1 s, program with 1,0 s
Motor Heat: 0 %
Force close: 0,0 s
Force open: 0,0 s
Door speed open: 35 Hz
Door speed close: 25 Hz
Door speed pre open: 15 Hz
Door speed pre close: 15 Hz
Minimum: 10 Hz
Run Timer: 40 Sek.
Position Sensor: Type 2ph sensor
Pulse count: 16
Position per meter: 2000
Scale: 0
Referenz: mec. Close
Ramp Acc open: 20 Hz/s
Ramp Acc close: 20 Hz/s
Dec open: 20 Hz/s
Dec close: 20 Hz/s
Dec Stop open: 30 Hz/s
Dec Stop close: 30 Hz/s
Dec emergency: 150 Hz/s
1.7 OVERVIEW CONTROL SYSTEM
1.7.1 Factory settings
Environment & storage
The door controller must not be installed in a housing that complies with protection class IP
65 or higher.
The door controller must not be installed outdoors.
The door controller must not be installed in hazardous areas.
Installation and operation may only be carried out in rooms with less than 90 % humidity.
The device must be stored under the same conditions as during operation.