49
DICTATOR Technik GmbH · +49 (0)821 246730 · [email protected] · www.dictator.de · 22.06.22
Technical manual: SQUARE 940-2
Indication
Action
Switching on for
the first time:
After switching on the controller for the first time, the status “E15“ = “Door
positions missing“ appears in the ready menu.
These are programmed via the Quick Setup, as described below
Setting
functionrelevant
parameters:
Before the actual commissioning, the following function-relevant parameters
must be set:
The number of encoder pulses to be entered can be found on the sticker on
the motor gear unit.
MIG - 120 - 19 - 016 7 = number of pulses 16
MIG - 120 - 19 - 005 7 = number of pulses 5
If none of the above designations can be found on the sticker, please contact
the technical customer service department.
The pulse number is entered in the “Pulse Count“ sub-item.
Please select the desired reference here. Recommended setting: Mechanical
stop in CLOSED position (Mec. Close).
Enter the corresponding motor speed here. This can be found on the rating
plate of the motor. The speed is entered in the subitem “Motor speed“.
6.2 PREPARATION