Hercules III User Manual Rev A.2
www.diamondsystems.com
Page
8
2.2
Data Acquisition
The functions listed below are applicable to the data acquisition versions only.
32 channel 16-bit A/D, 250KHz maximum sample rate
Single-ended or differential mode
Programmable input /-10V, +/-5V, +/-2.5V, +/-1.25V, 0-10V, 0-5V, 0-2.5V
Interrupt-based sampling with 2048-sample programmable FIFO
4 12-bit D/A channels
Output ranges: +/-10V, +/-5V, 0-10V, 0-5V
4 pulse width modulation circuits
Watchdog timer
1 24-bit and 1 16-bit counter/timer for A/D sample rate control, event counting, and programmable
interrupts
Auto-calibration with Universal Driver software support
2.3
Expansion Options
mSATA flashdisk mounting capability
PC/104-
Plus
expansion connector
PCIe MiniCard and GPS receiver sockets
2.4
Operating System Support
Windows Embedded Standard 7
Linux 2.6
Windows CE 6.0 R3
2.5
Mechanical, Electrical, Environmental
EBX form factor, 5.7
5”W x 8.0”H, identical to Hercules II
Fanless heat sink on top side
-40°C to +85°C ambient operating temperature without a fan
MIL-STD-202G shock and vibration compliant
Power input requirements: +7-40VDC +/- 5%