Table 10: Parts list with 4 speed motor (PSC) 

 

ITEM

PART #

DESCRIPTION

COMMENTS

1

B03622

HEAT EXCHANGER

Heat exchanger only

2

J06L002

SEAL STRIP,  DIA 1/8 x 25'

3

B03652-01

FRONT PANEL ASSEMBLY

Panel, insulation and labels included

4

B03667

FRONT PANEL INSULATION

5

B03637-01

BAFFLE, LATERAL

6

B03651-01

SIDE PANEL ASSEMBLY (RIGHT)

Panel, insulation and baffle included

7

B03666

SIDE PANEL INSULATION

8

B03455-01

ELECTRICAL KIT, BVSO INT.

9

F06F015

WASHER, ZINC 1 7/16"

10

Z99F061

OBSERVATION PORT

11

R02R004

HIGH LIMIT 195-30F,  7"

12

B03453

ELECTRICAL KIT, TT

13

B03454

ELECTRICAL KIT, BURNER

14

B03639

WIRE CHANNEL (BVSO/SWITCH)

15

B03630-01

BAFFLE

One baffle included

16

B03675

SMOKE OUTLET GASKET

17

B03662

RADIATOR BAFFLE

Item # 16 included

18

F07O001

FLANGE NUT, HEXAGONAL 3/8-16NC BRASS

19

F07F011

HEX NUT 3/8-16NC ZINC  

20

B01684

COVER, ELECTRICAL BOX

21

Z99F050

HANDLE , RECESSED BLACK

22

B03654-01

BLOWER DOOR ASSEMBLY

Door and labels included

23

B03680-02

REPLACEMENT BLOWER ASSEMBLY

Blower, motor  included

24

Z06G001

BLOCKED VENT SHUT-OFF BVSO-225

25

B03118-01

ELECTRICAL KIT, BVSO EXT.

26

L07F003

ROCKER SWITCH, DPST

27

L04I013

STRAIN RELIEF BUSHING

28

L04J001

CABLE CLAMP, 9/16" WHITE

29

B03640

WIRE CHANNEL, INT.

30

B03636

BLOWER DIVIDER

31

B30513

BLOWER SLIDE

One blower slide included

32

B03637-02

LATERAL BAFFLE

33

B03480-01

FILTER RACK KIT

34

B03635

FLOOR

35

B03651-02

SIDE PANEL ASSEMBLY (LEFT)

Panel, insulation and baffle included

36

B03653

REAR PANEL ASSEMBLY

Panel, insulation and baffles included

37

B03665

REAR PANEL INSULATION

38

B03638

REAR BAFFLE

39

B01682

SUPPORT, ELECTRONICS BOX

40

L01F009

TRANSFORMER, 120-24Volt, 40VA

41

B01683

ELECTRICAL BOX

42A

R99G004

ELECTRONIC BOARD, UTEC 1158-110

42B

R99G002

ELECTRONIC BOARD, HONEYWELL ST9103A

43

L01I002

CAPACITOR 7,5 MF

44

B01024

CAPACITOR HOLDER

45

B03669

ELECTRICAL KIT, BOARD

46

B03668-01

ELECTRICAL KIT, BLOWER

47

B03720-04

BLOWER ASSEMBLY WITH LABEL

Housing, wheel and label included

48

L06H004

MOTOR 1/2 HP 4V DD

49

B01888

MOTOR SUPPORT ASSEMBLY                        

Legs, band & hardware included

50

R02R007

HIGH LIMIT 120-20F, 1.75''

51

B03641

BLOWER SLIDE

One blower slide included

DOWNFLOW BASE

B03464-02

HORIZONTAL FLOW BASE

B00488-01

VENT TERMINAL KIT 4''

For sealed combustion

4" INSULATED FLEX VENT 10ft

For sealed combustion (B02551-09)

4" INSULATED FLEX VENT 20ft

For sealed combustion (B02551-10)

BECKETT NX BURNER (0.60-60A NOZZLE)

RIELLO 40-F5 BURNER (0.60-70A NOZZLE)

RIELLO 40-BF5 BURNER (0.60-70A NOZZLE)

For sealed combustion

PROTECTION PLATE BURNER NX

For down flow instalation only

B03789

N01F052

KLABR0401RLO

N01J052

KLABR0201BEC

HFB-101

KLASB0701DET

VTK-098

KLAVT0101DET

ACCESSORIES

DFB-103

KLASB0901DET

N01F051

KLABR0301RLO

IFV-098-10

KLAFV0101DET

IFV-098-20

KLAFV0201DET

 

 

B50091D

Summary of Contents for AMP112SD

Page 1: ...L FOR THE INSTALLATION SERVICING OF THE FURNACE AND KEEP THE DOCUMENT NEAR THE UNIT FOR FUTURE REFERENCE HOMEOWNER PLEASE KEEP THIS MANUAL NEAR THE FURNACE FOR FUTURE REFERENCE Attention Do not tamper...

Page 2: ...tilation air openings in a closet door 4 Figure 2 Upflow installation 4 Figure 3 Downflow installation 5 Figure 4 Horizontal installation 5 Figure 5 Thermostat wiring heating and air conditioning with...

Page 3: ...formation such as the model and serial numbers of the furnace WARNING Installations and repairs performed by unqualified persons can result in hazards to them and to others Installations must conform...

Page 4: ...designed for outdoor installation It must be installed in such a manner as to protect its electrical components from water Outdoor installation will lead to a hazardous electrical condition and to pre...

Page 5: ...TION The exterior of the unit must have an uninterrupted ground to minimize the risk of bodily harm if ever an electrical problem develops A green ground screw is supplied with the control box for tha...

Page 6: ...Before starting the burner for the first time adjust the air and turbulator settings to those listed in this manual Once the burner becomes operational final adjustments will be required Refer to sect...

Page 7: ...ormance Test The purpose of the following test is to check that the electrical outlet on the furnace designated to the BVSO is functional 1 Start up the burner 2 Remove the three pole plug from the BV...

Page 8: ...distance 2 10 DUCTING WARNING Poisonous carbon monoxide gas hazard DO NOT draw return air from inside a closet or utility room Return air MUST be sealed to the furnace casing Failure to properly seal...

Page 9: ...o do so can result in death or bodily injury 2 13 1 Humidifier HUM The 120 VAC HUM terminal on the electronic board of the blower is tied directly to terminal 8 of the 9 terminal connector of the elec...

Page 10: ...n the instructions provided with the burner 3 3 CHECKS AND ADJUSTMENTS 3 3 1 Purging The Oil Line Open the bleed port screw and start the burner Allow the oil to drain into a container for at least 10...

Page 11: ...the obstruction and the burner should restart after a few minutes The time required for the restart also depends on the adjustment of the blower OFF delay 3 3 9 Restart After Burner Failure 1 Set the...

Page 12: ...obstruction inside the heat transfer tube 7 Re mount lock and fasten the control box with the 2 screws removed in step 4 8 Re attach the assembly cover with the screws removed in step 2 9 Re establish...

Page 13: ...vice telephone Day Night Dealer name and address START UP RESULTS Nozzle Pressure lb po 2 Burner adjustments Primary air Fine air Drawer Assembly CO2 Smoke scale Bacharach Gross stack temperature F Am...

Page 14: ...ard and Canadian regulation 85 5 85 0 85 5 85 0 AFUE From ASHRAE 103 standard and US regulation 85 2 85 0 85 2 85 0 Volts Hertz Phase Rated current Amps Minimum ampacity for wire sizing Amps Max fuse...

Page 15: ...nOn D elay CFMLevel Time ShortR unOn Delay C FMLevel Time Off Delay CFMLevel Time A 1 OFF 2 OFF 0 68 13 45sec 19 60sec 38 3min B 1 ON 2 OFF 0 80 13 45sec 19 30sec 38 3min C 1 OFF 2 ON A ll 13 45sec 10...

Page 16: ...ANDWARM AIRDUCTWITHIN6ft OFFURNACE1 5 08 cm 2 2 54cm 1 5 08 cm 2 BOTTOM FURNACE2 2 54cm 1 3 5 08 cm 2 4 BACK FURNACE OP P OSITESIDEOFTHEBURNE R 1 7 62 cm 3 7 62cm 3 7 62 cm 3 PLE NUMORHORIZONTALWARM A...

Page 17: ...17 Figure 9 Furnace Dimensions...

Page 18: ...18 Figure 10 Wiring Diagram 4 Speed Motor PSC...

Page 19: ...19 Figure 11 Wiring Diagram Variable Speed Motor ECM...

Page 20: ...20 Figure 12 Parts list with 4 speed motor PSC B50091C...

Page 21: ...er slide included 32 B03637 02 LATERAL BAFFLE 33 B03480 01 FILTER RACK KIT 34 B03635 FLOOR 35 B03651 02 SIDE PANEL ASSEMBLY LEFT Panel insulation and baffle included 36 B03653 REAR PANEL ASSEMBLY Pane...

Page 22: ...22 Figure 13 Parts list with variable speed motor ECM B50092C...

Page 23: ...IDE One blower slide included 31 B03637 02 LATERAL BAFFLE 32 B03480 01 FILTER RACK KIT 33 B03635 FLOOR 34 B03651 02 SIDE PANEL ASSEMBLY LEFT Panel insulation and baffle included 35 B03653 REAR PANEL A...

Page 24: ...DER LE DOCUMENT PR S DE L UNIT POUR R F RENCES ULT RIEURES PROPRI TAIRE S V P GARDER CE MANUEL PR S DE L UNIT POUR R F RENCES ULT RIEURES Attention Ne pas alt rer votre unit ou ses contr les Appeler u...

Page 25: ......

Page 26: ...ions et localisation ouvertures de ventilation dans la porte du placard 6 Figure 2 D bit ascendant 6 Figure 3 D bit descendant 6 Figure 4 D bit horizontal 6 Figure 5 Branchement du thermostat chauffag...

Page 27: ...v Le filtre air comment le changer v rifier mensuellement et nettoyer ou changer si n cessaire g Avant d appeler pour le service ayez en main la page de la fiche technique section 5 note de ce manuel...

Page 28: ...s de chauffage air chaud et syst me d air climatis ANSI NFPA 211 Chemin e Foyers vents et appareils de chauffage ANSI NFPA 70 Code National d lectricit CSA C22 1 or CSA C22 10 Code Canadien d lectrici...

Page 29: ...tre install dans le m me sens peu importe l orientation de la fournaise Voir figure 3 pour plus de d tails La plaque de protection B03789 doit tre install e sur le couvercle de plastique du br leur B...

Page 30: ...chauffage central utilisez seulement du fil de cuivre r sistant la m me temp rature que les fils d origine 2 4 INSTALLATION DU THERMOSTAT L installation d un thermostat de contr le de la temp rature d...

Page 31: ...u br leur pour plus de d tail concernant l ajustement du d lai post purge 2 6 VACUATION MISE EN GARDE Risque d empoisonnement par monoxyde de carbone Lire et suivre toutes les instructions contenues d...

Page 32: ...UALIFI 2 8 APPROVISIONNEMENT EN AIR DE COMBUSTION ET VENTILATION MISE EN GARDE Risque d empoisonnement par monoxyde de carbone R f rer aux codes d installation des appareils au mazout ANSI NFPA 31 aux...

Page 33: ...tallations ayant un r servoir de mazout situ sous le niveau du br leur doivent utiliser une ligne de retour de mazout vers le r servoir avec une pompe appropri e une l vation de 2 4 m 8 et plus requi...

Page 34: ...auffage Position interrupteurs DIP 1 2 POSITION Consommation USGPH OFF OFF A 0 68 ON OFF B 0 80 OFF ON C 0 68 ON ON D 0 80 Ajustements suppl mentaires pour une l vation de temp rature de l air sup rie...

Page 35: ...huile est ouverte 5 Le bouton Reset du br leur est bien enfoncer ou r armer 6 L ajustement d air pr liminaire du br leur est conforme aux tableaux des sp cifications de ce manuel 7 L ajustement des v...

Page 36: ...evant du r gulateur la verticale voir les instructions incluses avec le r gulateur Ajuster le r gulateur de tirage apr s que l appareil ait fonctionn e au moins cinq minutes et r gl entre 0 025 et 0 0...

Page 37: ...les fusibles et disjoncteur 3 V rifier si l interrupteur d alimentation principal de la fournaise est en position ON 4 Ajuster le thermostat au dessus de la temp rature ambiante 5 Si l allumage du br...

Page 38: ...tre du r servoir Remplacer le filtre du r servoir au besoin Suivre les instructions du fabriquant Filtre secondaire Remplacer les cartouches des filtres de 10 microns ou moins une fois par ann e Suivr...

Page 39: ...103 et des lois am ricaines 85 2 85 0 85 2 85 0 BR LEUR RIELLO MOD LE 40 BF5 vacuation directe DV Longueur d insertion du tube du br leur pouces Gicleur Delavan 0 60 70A 0 70 70A 0 60 70A 0 70 70A Pr...

Page 40: ...On Niveau PCM Temps D lai Off Niveau PCM Temps A 1 OFF 2 OFF 0 68 13 45 sec 19 60 sec 38 3 min B 1 ON 2 OFF 0 80 13 45 sec 19 30 sec 38 3 min C 1 OFF 2 ON Tous 13 45 sec 100 0 sec 100 2 min D 1 ON 2 O...

Page 41: ...ISE 1 5 08 cm 2 2 54 cm 1 5 08 cm 2 DESSOUS FOURNAISE 2 2 54 cm 1 3 5 08cm 2 4 ARRI RE FOURNAISE C T OPPOS DUBR LEUR 1 7 62 cm 3 7 62 cm 3 7 62 cm 3 PL NUMOU CONDUIT D AIR CHAUDHORIZONTAL 6 pi DE LA F...

Page 42: ...19 Figure 9 Dimensions de la fournaise...

Page 43: ...20 Figure 10 Diagramme lectrique avec moteur 4 vitesses PSC...

Page 44: ...21 Figure 11 Diagramme lectrique avec moteur vitesse variable ECM...

Page 45: ...22 B50091C Figure 12 Liste de pi ces avec moteur 4 vitesses PSC...

Page 46: ...une seule glissi re 32 B03637 02 DEFLECTEUR LATERAL 33 B03480 01 KIT SUPPORT A FILTRE 34 B03635 PLANCHER 35 B03651 02 ASS PANNEAU COTE GAUCHE Comprend panneau isolation et d flecteur 36 B03653 ASS PA...

Page 47: ...24 B50092C Figure 13 Liste de pi ces avec moteur vitesse variable ECM...

Page 48: ...TEUR Comprend une seule glissi re 31 B03637 02 DEFLECTEUR LATERAL 32 B03480 01 KIT SUPPORT A FILTRE 33 B03635 PLANCHER 34 B03651 02 ASS PANNEAU COTE GAUCHE Comprend panneau isolation et d flecteur 35...

Reviews: