6 Operation
Operating Instructions inLab MC X5
6.2 Machining processes
båÖäáëÜ
2. Loosen the three screws (A) that are located on the fixing ring of the
workpiece holder using the torque wrench for the tool holder.
3. Turn the fixing ring counterclockwise and remove the fixing ring of the
workpiece holder.
4. Now insert the multi-block holder, making sure that the multi-block
holder is parallel to the base and is not slanted. Ensure clean contact
surfaces. Make sure that the notch on the block holder is on the
bottom non-engraved side of the multi-block holder. Rotate the multi-
block holder into the final position using a light rotating movement on
the block in the block fixation until it locks into place.
A
A
Bottom multi-block holder
B
Top multi-block holder