Page 1: ...Barcode Handy Scanner SE1 BB User s Manual...

Page 2: ...any means without permission in writing from the publisher QBdirect is a trademark of DENSO WAVE INCORPORATED iPad and iPhone are trademarks of Apple Inc Microsoft Windows is a trademark of Microsoft...

Page 3: ...Status 12 3 6 Scanning When the Bluetooth Wireless Link is Broken 13 Chapter 4 Configuring Scanner Parameters 14 Chapter 5 Scanning Control 15 5 1 Trigger Switch Control 15 Chapter 6 Magic Key Control...

Page 4: ...Appendix 1 Specifications 68 Appendix 2 Control Commands 69 Appendix 3 Bluetooth Glossary 71...

Page 5: ...rocessing system s or equipment or software not supplied from DENSO WAVE ii the use of DENSO WAVE s products in a manner for which the same were not intended nor designed or iii any modification of DE...

Page 6: ...se conditions that could cause serious bodily injury or death if the instructions are not followed correctly Alerts you to those conditions that could cause minor bodily injury or substantial property...

Page 7: ...ever put the battery into a microwave oven or high pressure container Doing so could cause the batteries to break generate heat rupture or burn Avoid dropping the battery or letting it undergo any sho...

Page 8: ...ing remove the battery and contact your nearest dealer Failure to do so could cause fire or electrical shock Do not use the scanner where any inflammable gases may be emitted Doing so could cause fire...

Page 9: ...ure changes Moisture will get into the scanner resulting in malfunction fire or electrical shock Do not place the scanner anyplace where it may be subjected to oily smoke or steam e g near a cooking r...

Page 10: ...cracked housing electrical shock or fire Do not use the scanner with anti slip gloves containing plasticizer The scanner housing may be broken creating injuries electrical shock or fire When taking c...

Page 11: ...er SE1 BB 2 Communications adapter BA series Components required for individual interfaces For RS 232C interface 3 RS 232C interface cable CBBA RS2000 9 For USB keyboard or USB COM interface 4 USB int...

Page 12: ...times block wireless networking The following environments can sometimes block wireless networking Metal objects or particles in the vicinity Metal walls around the area Excessive vibration The commun...

Page 13: ...ate with a cotton swab or the similar soft one gently If sand or hard particles have accumulated never rub the plate doing so will scratch or damage it Blow the particles away with an airbrush or a so...

Page 14: ...eaks the link Pressing this key quickly while the scanner is turned on allows the operator to check the remaining battery level Strap hole Use this hole for attaching the optional strap Indicator LED...

Page 15: ...y cover lock 1 and remove the battery cover 2 2 Make sure that the new batteries are in the correct orientation when inserting them Insert the new batteries in the direction indicated by the arrow The...

Page 16: ...re to thoroughly read the User s Manual for the batteries and follow written instructions to ensure correct use A rechargeable nickel metal hydride battery eneloop battery capacity 1900 mAh or equival...

Page 17: ...the scanner is turned off pressing the magic key will start the Bluetooth wireless link Using the scanner when End operation is selected requires first reading the Start operation Bar Code symbol give...

Page 18: ...o the scanner If barcodes are tilted at an angle or bent they sometimes cannot be scanned Barcodes sometimes cannot be scanned in the direct sunlight or in very bright locations Either move the barcod...

Page 19: ...Bluetooth radio waves 2400 to 2483 5 MHz maximum 2 5 mW present a potential safety risk This scanner interprets the End operation Bar Code symbol given in Section 11 2 according to the procedure in S...

Page 20: ...he number of input digits and data integrity and adopt measures such as correcting the erroneous input data When connecting the scanner to an iPhone iPad Android or Windows device The scanner can be c...

Page 21: ...con 2 Select Bluetooth 3 Select SE1 4 When the PIN code confirmation is displayed enter 1234 5 When the scanner is successfully connected SE1 is displayed on the paired device Connect is displayed on...

Page 22: ...a while the scanner sounds the beep twice 4 The next time connecting to the device simply press the trigger switch Only when connecting with the same device When using the configuration software Scan...

Page 23: ...Bluetooth address to the scanner When using a commercially available code generator generate it in the following format Code type Data format Code 128 Code Set A ADDRXXXXXXXXXXXX Note XXXXXXXXXXXX sh...

Page 24: ...uccessful connection Tip In addition to As a master and As a slave parameters the configuration software Scan Tune App provides a choice of No slave master configuration change that prevents the Bluet...

Page 25: ...en is set scan the Scan w Bluetooth link broken Bar Code symbol given in Section 11 2 and its procedure in Section 11 1 scan the Cancel Scan w Bluetooth link broken Bar Code symbol to set cancel and t...

Page 26: ...a transfer is not This function can be switched only with the Bar coded parameter menu Scan w Bluetooth link broken Allows the scanner to scan codes with the Bluetooth wireless link broken It also dis...

Page 27: ...iguration software or batch process Bar Code symbols breaks the Bluetooth wireless link so it is necessary to establish the link again after customizing To prevent the Bluetooth wireless link from get...

Page 28: ...nning is successfully completed or after approximately five seconds elapsed with the trigger switch pressed The scanner goes to the Ready state if the trigger switch is released before five seconds el...

Page 29: ...oth wireless link To end the Bluetooth wireless link hold down the magic key for at least five seconds Breaking of the Bluetooth wireless link by using the magic key can be disabled in the configurati...

Page 30: ...rohibit If the scanner fails to extract an AI prefixed string when the Data transfer regardless of error result is permitted it outputs the data read as is without editing Delimiters Header terminator...

Page 31: ...1 11 17 STX 94901234567894 030808 040208 ETX 17 11 STX 040208 030808 ETX 17 17 STX 040208 040305 ETX 12 Error 01 12 Error Data transfer regardless of error result Prohibit 01 01 Error 01 11 17 STX 949...

Page 32: ...itions Data read Output data 0194901234567894110308081303 081017040208 STX 01 94901234567894 11 030808 13 03 0810 17 040208 ETX Data transfer regardless of error result Prohibit 0194901234567894110308...

Page 33: ...e YYMMDD 20 n2 n2 Product Variant 21 n2 an 20 Serial Number 22 n2 an 29 HIBCC Health Industry Business Communication Council Quantity Date Batch and Link 23n n3 n 19 Batch or Lot Number Transitional U...

Page 34: ...34n n4 n6 Area Square Meters Symbology 335n n4 n6 Gross Volume Liters 336n n4 n6 Gross Volume Cubic Meters 337n n4 n6 Kilograms per Square Meter pressure 340n n4 n6 Gross Weight Pounds 341n n4 n6 Leng...

Page 35: ...ngle Monetary Area 393n n4 n3 n15 Amount Payable for a Variable Measure Trade Item and ISO Currency Code 400 n3 an 30 Customer s Purchase Order Number 401 n3 an 30 Consignment Number 402 n3 n17 Shipme...

Page 36: ...Mobile Telephone Identifier 8003 n4 n14 an 16 EAN UCC Global Returnable Asset Identifier GRAI 8004 n4 an 30 EAN UCC Global Individual Asset Identifier GIAI 8005 n4 n6 Price Per Unit of Measure 8006 n4...

Page 37: ...of digits in data read is less than the maximum number of digits defined for the AI then the output contains data read up to a GS 1Dh The AI definition is continuously updated via GS1 Therefore depend...

Page 38: ...cations error has occurred an invalid control command is received a Bluetooth wireless link is broken you press the trigger switch and the magic key for three seconds or more and the power of the scan...

Page 39: ...tion software Scan Tune App Note Enabling the Bluetooth interface with the Start operation Bar Code symbol allows the beeper volume to be adjusted Each time the Beeper volume Bar Code symbol is scanne...

Page 40: ...ine battery once when battery type is set to rechargeable nickel hydride battery The indicator LED flashes in orange when the battery voltage has dropped flashing at long intervals the scanner turns i...

Page 41: ...hen the configuration software Scan Tune App starts up or any setting is newly reflected when the parameter values are saved by a PW command refer to Appendix 2 when the scanner failed to save paramet...

Page 42: ...e you can select either the non acknowledge mode or the ACK NAK mode Non acknowledge mode default The scanner transfers scanned code data regardless of the CTS signal status ACK NAK mode The scanner t...

Page 43: ...The following describes each field in detail 1 Header Terminator The following choices are available SPP profile Header None default STX or User Selection Terminator CR default None LF CR LF ETX or Us...

Page 44: ...ith 5 digit add on Add on None Without add on Linear component B With 2 digit add on Add on None Linear component B EAN 8 With 5 digit add on Add on None Standard 2 of 5 short H Standard 2 of 5 normal...

Page 45: ...the padding character 0 number system character S and the check digit to the host Disabling the transmission of the number system character S automatically disables the transmission of the padding ch...

Page 46: ...length S Number system character UPC E with add on With 2 digit add on Conversion to UPC A disabled 0 X1 X2 X3 X4 X5 X6 C D X7 X8 Conversion to UPC A enabled X6 0 2 0 S X1 X2 X6 0 0 0 0 X3 X4 X5 C D...

Page 47: ...on to ISBN ISSN enabled To the ISBN format X1 X2 X3 X4 X5 X6 X7 X8 X9 C D 1 To the ISSN format X1 X2 X3 X4 X5 X6 X7 C D 1 1 Check digits in the ISBN ISSN format are calculated MOD 11 and transferred t...

Page 48: ...ata including the start stop codes You can select whether or not to transmit the start stop codes Code 128 GS1 128 EAN 128 The scanner transmits read code data starting from the character following th...

Page 49: ...ode Section 7 1 Double read enabled Period of double read prevention Period of double read prevention 0 1 to 9 9 sec 0 3 sec Section 2 4 2 Communications modes Items Parameters Defaults Refer to BA10...

Page 50: ...102 key type Italian 102 key type Swedish 102 key type Keyboard type Japanese 106 key type Section 9 3 2 Inboard numeric keys Numeric key selection 0 to 9 transmission format Numeric keypad Section 9...

Page 51: ...tion substitutes E5h to FDh data with the special keys as listed below and transmits the substituted data to the host The Left SHIFT Left CTRL and Left ALT are transmitted as a simultaneous depression...

Page 52: ...address Connection target s address None Section 3 2 2 minutes 4 minutes 10 minutes Timeout period for slave to wait for a connection request 30 minutes Section 9 1 Enable Clear the transfer buffer w...

Page 53: ...40 6 Data transmission format for SPP Profile Items Parameters Defaults Refer to None STX Header User defined None ETX CR LF CR LF Terminator User defined Section 9 4 1...

Page 54: ...Items Parameters Defaults Refer to None STX ETX CR LF CR LF TAB ESC ENTER Right CTRL Header User defined None STX ETX CR LF CR LF TAB ESC ENTER Right CTRL Terminator User defined Section 9 4 1 Can be...

Page 55: ...ransmission of check digit Disable Enable UPC A transmission of number system character Disable Enable UPC A transmission of the leading character Disable Section 9 4 4 Enable EAN 13 transmission of c...

Page 56: ...ction 11 2 Minimum number of readable digits for Interleaved 2 of 5 4 digits Maximum number of readable digits for Interleaved 2 of 5 4 to 99 digits 99 digits See Note 1 Note 1 The parameter setting r...

Page 57: ...digits that the scanner can actually read Code 39 Items Parameters Defaults Refer to Enable without the check digit Enable with the check digit Reading Code 39 Disable Enable Code 39 transmission of...

Page 58: ...actually read Note 2 Using the Bar coded parameter menu enables or disables reading of both Code 128 and GS1 128 EAN 128 at the same time Code 93 Items Parameters Defaults Refer to Enable Reading Code...

Page 59: ...1 transmission of GS1 DataBar Expanded Disable Section 11 2 Minimum number of readable digits for GS1 DataBar Expanded GS1 DataBar Expanded Stacked Note 1 Note 2 1 digit Maximum number of readable dig...

Page 60: ...m beeping tone approx 2 2 kHz Beeping tone High beeping tone approx 4 3 kHz Short approx 60 ms Medium approx 80 ms Beeper beep time Long approx 120 ms High Medium Beeper volume Low Section 8 1 Single...

Page 61: ...er Terminator Comma AI split mode Delimiter Tab 09h Section 7 1 Note 1 For details about AI candidates refer to Chapter 7 Section 7 1 1 3 AI table 14 Switching to sleep mode for power saving and auto...

Page 62: ...ymbols End setting Scan the End setting Bar Code symbol Three beeps Scanning the All defaults Bar Code symbol from the Bar coded parameter menu makes all items in the menu revert to the factory defaul...

Page 63: ...default is High Beeper volume To set the parameters simply scan the Bar codes below Scanning Start setting Bar Code symbol and End setting Bar Code symbol is not required Easy connection setup To set...

Page 64: ...51 Menu control Starting Ending the Setting Procedure and Reverting to Defaults Start setting Cancel All defaults End setting...

Page 65: ...oken Scanning the Scan w Bluetooth link broken Bar Code symbol allows the scanner to scan codes with the Bluetooth wireless link broken With this setting selected data transfer with the host computer...

Page 66: ...ns parameters Procedure Non acknowledge mode default ACK NAK mode Header SPP Profile None default STX Terminator SPP Profile ETX CR default LF CR LF None Keyboard type HID Profile Japanese 106 key typ...

Page 67: ...54 Header HID Profile None default STX ETX CR LF CR LF TAB ESC ENTER Right CTRL...

Page 68: ...55 Terminator HID Profile None STX ETX CR LF CR LF TAB ESC Enter default Right CTRL...

Page 69: ...ave to wait for a connection request 2 minutes default 4 minutes 10 minutes 30 minutes Data transmission format Transmission of code ID mark Disable default Enable Transmission of the number of digits...

Page 70: ...on Enable with add on 2 digits Disable with add on 2 digits default Enable with add on 5 digits Disable with add on 5 digits default Scanning Standard 2 of 5 Enable without the check digit Enable with...

Page 71: ...t Enable with the check digit Disable Transmission of Interleaved 2 of 5 check digit Enable default Disable Scanning Codabar NW 7 Enable without the check digit default Enable with the check digit Dis...

Page 72: ...Transmission of a b c d enabled default Transmission of A B C D enabled Disable Conversion from Code 39 to Code 32 Enable Disable default Transmission of the leading A of Code 32 Enable Disable defau...

Page 73: ...Enable with the check digit Disable Transmission of Code 39 check digit Enable default Disable Transmission of start stop codes for Code 39 Enable default Disable Conversion to Code 39 Full ASCII Enab...

Page 74: ...Convert to GS1 before Transmission default Disable Transmission of FNC1 for GS1 128 EAN 128 Convert to GS1 before Transmission default Disable Scanning MSI Enable without C D Enable with C D 1 digit E...

Page 75: ...le Scanning GS1 DataBar Omnidirectional GS1 DataBar Truncated Enable Disable default Scanning GS1 DataBar Stacked GS1 DataBar Stacked Omnidirectional Enable Disable default Scanning GS1 DataBar Limite...

Page 76: ...Stacked Enable Disable default FNC1 transmission of GS1 DataBar Expanded Convert to GS1 before Transmission default Disable Other settings Trigger switch control Auto off mode default Alternate switch...

Page 77: ...rol Enable default Disable Beeper frequency Low beeping tone Medium beeping tone High beeping tone default Beeper beep time Short 60 ms Medium 80 ms default Long 120 ms Indicator LED control Enable de...

Page 78: ...65 Battery type setting LR6 AA alkaline battery default AA rechargeable nickel hydride battery Remaining battery level check Enable default Disable...

Page 79: ...eless link is not established Establish the Bluetooth wireless link with the target Bluetooth device Problem 3 Code data not displayed on the computer screen correctly Probable cause What to do The ta...

Page 80: ...ickel metal hydride battery is used Discharge the AA rechargeable nickel metal hydride battery using the dedicated charger for example and then recharge the battery before using it again For details r...

Page 81: ...nts Main power LR6 AA alkaline battery 2 or AA rechargeable nickel metal hydride battery 2 A rechargeable nickel metal hydride battery eneloop battery capacity 1900 mAh or equivalent is recommended Ma...

Page 82: ...ransfer Direction Control Commands Scanner Host Function B1 B2 B3 Note 1 Note 2 Sound the beeper Within 100 ms from the receipt of any of the B1 B2 and B3 commands the scanner beeps for the period spe...

Page 83: ...Scan Tune App Response from the scanner Ver n nn mm where n nn mm is version number Ex Ver 1 00 00 and mm is parameter setting version ID Request for scanner ID serial number Response from the scanner...

Page 84: ...oth devices in pairing Once authentication is performed no Bluetooth passkey input is required for the next authentication Local Name Bluetooth Device Name This is a user friendly name for the Bluetoo...

Page 85: ...Barcode Handy Scanner SE1 BB User s Manual First Edition November 2014 DENSO WAVE INCORPORATED...

Page 86: ...1 Yoshiike Kusagi Agui cho Chita gun Aichi 470 2297 Japan http www denso wave com...