266
Script Commands
addPhysicalDisks
Adds new physical disks to the virtual disk.
Specify the enclosure ID and slot ID for each
physical disk that you assign to the virtual
disk. Enclosure ID values are 0 to 99. Slot ID
values are 0 to 31. You must put brackets ([ ])
around the enclosure ID values and the slot
ID values. Use with the
addCapacity
parameter if you must specify additional
physical disks to accommodate the new size.
consistencyCheckEnabled
Turns consistency checking during a media
scan on or off. To turn consistency checking
on, set to
TRUE
. To turn consistency
checking off, set to
FALSE
.
segmentSize
Amount of data (in kilobytes) that the RAID
controller module writes on a single physical
disk in a virtual disk before writing data on the
next physical disk. Valid values are
8
,
16
,
32
,
64
,
128
,
256
, or
512
. For information about
the
segmentSize
parameter, see "Using the
Auto Configure Command" on page 54.
userLabel
Specifies the new name to give an existing
virtual disk. You must put quotation marks
(" ") around the new virtual disk name.
preReadRedundancyCheck
The setting to check the consistency of RAID
redundancy data on the stripes during read
operations. Do not use this operation for
nonredundant virtual disks, for example RAID
Level 0. To check redundancy consistency, set
this parameter to
TRUE
. For no stripe
checking, set this parameter to
FALSE
.
Parameter
Description
book.book Page 266 Wednesday, June 8, 2011 12:20 PM
Summary of Contents for PowerVault MD3600f Series
Page 1: ...Dell PowerVault Modular Disk Storage Arrays CLI Guide ...
Page 44: ...44 About the Script Commands ...
Page 114: ...114 Using the Remote Replication Premium Feature ...
Page 311: ...Script Commands 311 ...
Page 312: ...312 Script Commands ...
Page 318: ...318 Sample Script Files ...
Page 328: ...Index 328 ...