Script Commands
249
Set Session
This command defines how you want the current script engine session to run.
Syntax
set session errorAction=(stop | continue)
password=”
storageArrayPassword
”
performanceMonitorInterval=
intervalValue
performanceMonitorIterations=
iterationValue
Parameters
Parameter
Description
errorAction
How the session responds if an error is
encountered during processing. You can
choose to stop the session if an error is
encountered, or you can continue the
session after encountering an error. The
default value is
stop
. (This parameter
defines the action for execution errors,
not syntax errors. Some error conditions
might override the
continue
value.)
password
The password for the storage array.
Enclose the password in double
quotation marks (“ ”).
performanceMonitorInterval
The frequency of gathering performance
data. Enter an integer value for the
polling interval, in seconds, for which you
want to capture data. The range of values
is 3 to 3600 seconds. The default value is
5 seconds.
performanceMonitorIterations
The number of samples to capture. Enter
an integer value. The range of values for
samples captured is 1 to 3600. The
default value is 5.
book.book Page 249 Wednesday, June 8, 2011 12:20 PM
Summary of Contents for PowerVault MD3600f Series
Page 1: ...Dell PowerVault Modular Disk Storage Arrays CLI Guide ...
Page 44: ...44 About the Script Commands ...
Page 114: ...114 Using the Remote Replication Premium Feature ...
Page 311: ...Script Commands 311 ...
Page 312: ...312 Script Commands ...
Page 318: ...318 Sample Script Files ...
Page 328: ...Index 328 ...