22
About Your System
Alert! iDRAC6 not
responding.
Rebooting.
The optional iDRAC6 is not
responding to BIOS
communication either
because it is not functioning
properly or has not
completed initialization.
The system reboots.
Wait for the system
to reboot.
Alert! iDRAC6 not
responding.
Power required
may exceed PSU
wattage.
Alert!
Continuing
system boot
accepts the risk
that system may
power down
without warning.
The optional iDRAC6 stops
responding.
The optional iDRAC6 was
remotely reset while
system was booting.
After AC recovery, the
optional iDRAC6 takes
longer than normal to boot.
Remove AC power to the
system for 10 seconds and
restart the system.
Alert! Node
Interleaving
disabled! Memory
configuration
does not support
Node
Interleaving.
The memory configuration
does not support node
interleaving, or the
configuration has changed
(for example, a memory
module has failed) so that
node interleaving cannot be
supported. The system still
runs, but without node
interleaving.
Ensure that the memory
modules are installed in a
configuration that supports
node interleaving.
Check other system
messages for additional
information for possible
causes. For memory
configuration information,
see "General Memory
Module
Installation Guidelines" on
page 81. If the problem
persists,
see "Troubleshooting System
Memory" on page 137.
Message
Causes
Corrective Actions
book.book Page 22 Wednesday, May 12, 2010 9:26 PM
Summary of Contents for PowerVault DL2200 CommVault
Page 10: ...10 Contents ...
Page 38: ...38 About Your System ...
Page 60: ...60 Using the System Setup Program and UEFI Boot Manager ...
Page 128: ...128 Installing System Components ...
Page 146: ...146 Troubleshooting Your System ...
Page 156: ...156 Jumpers and Connectors ...
Page 158: ...158 Getting Help ...
Page 164: ...164 Index ...