About Your System
125
Error: Incorrect
memory
configuration.
DIMMs must be
installed in pairs
of matched memory
size, speed, and
technology.
Mismatched or
unmatched DIMMs
installed; faulty or
improperly seated memory
modules.
Ensure that all pairs of
memory modules are of the
same type and size, and that
they are properly installed.
See "System Memory" on
page 171 If the problem
persists, see
"Troubleshooting Blade
Memory" on page 319.
Error: Incorrect
memory
configuration.
System halted.
Less than 512 MB of
memory installed.
Add memory modules to
achieve a configuration
supported by the system.
See "System Memory" on
page 171.
Error: Memory
failure detected.
Memory size
reduced. Replace
the faulty DIMM as
soon as possible.
Faulty or improperly
seated memory modules.
See "Troubleshooting Blade
Memory" on page 319.
Error programming
flexAddress (MAC)
for
bus
,
device
,
function
.
FlexAddress (virtual
MAC) is not supported on
the specified device.
Information only.
Error programming
flexAddress (iSCSI
MAC) for
bus
,
device
,
function
.
FlexAddress (virtual
MAC) is not supported on
the specified device.
Information only.
Error resetting
NIC after
programming
flexAddress for
bus
,
device
,
function
.
FlexAddress (virtual
MAC) is not supported on
the specified device.
Information only.
Table 1-27. Blade Messages
(continued)
Message
Causes
Corrective Actions
Summary of Contents for PowerEdge M620
Page 1: ...Dell PowerEdge Modular Systems Hardware Owner s Manual ...
Page 60: ...60 About Your System Figure 1 24 Example of PowerEdge M610x Port Mapping of Blade 2 ...
Page 68: ...68 About Your System Figure 1 26 Example of Half Height Blade Port Mapping ...
Page 136: ...136 About Your System ...
Page 286: ...286 Installing Blade Components ...
Page 308: ...308 Installing Enclosure Components ...
Page 330: ...330 Running System Diagnostics ...
Page 360: ...360 System Board Information ...
Page 362: ...362 Getting Help ...
Page 368: ...Index 368 V video controller installing 273 ...