112
About Your System
E201D Shutdown test
failure.
Power cycle
AC.
BIOS shutdown test failure. Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 361.
E201E POST memory
test failure.
Check DIMMs.
BIOS POST memory test
failure.
See "Troubleshooting
Blade Memory" on
page 319.
If the problem persists,
see "Getting Help" on
page 361.
E2020 CPU
configuration
failure.
Check screen
message.
Processor configuration
failure.
Check screen for specific
error messages. See
"Troubleshooting
Processors" on page 322.
E2021 Incorrect
memory
configur-
ation. Review
User Guide.
Incorrect memory
configuration.
Check screen for specific
error messages (see
"Troubleshooting Blade
Memory" on page 319).
E2022 General
failure
during POST.
Check screen
message.
General failure after video. Check screen for specific
error messages.
E2110 Multibit
Error on DIMM
##. Reseat
DIMM.
The DIMM in slot "##"
has had a multi-bit error
(MBE).
See "Troubleshooting
Blade Memory" on
page 319.
Table 1-26. LCD Status Messages
(continued)
Code
Text
Cause
Corrective Actions
Summary of Contents for PowerEdge M620
Page 1: ...Dell PowerEdge Modular Systems Hardware Owner s Manual ...
Page 60: ...60 About Your System Figure 1 24 Example of PowerEdge M610x Port Mapping of Blade 2 ...
Page 68: ...68 About Your System Figure 1 26 Example of Half Height Blade Port Mapping ...
Page 136: ...136 About Your System ...
Page 286: ...286 Installing Blade Components ...
Page 308: ...308 Installing Enclosure Components ...
Page 330: ...330 Running System Diagnostics ...
Page 360: ...360 System Board Information ...
Page 362: ...362 Getting Help ...
Page 368: ...Index 368 V video controller installing 273 ...