134
Troubleshooting
The cache contains
dirty data, but some
virtual disks are
missing or will go
offline, so the cached
data can not be
written to disk. If
this is an unexpected
error, then please
power off your system
and check your cables
to ensure all disks
are present. If you
continue, the data in
cache will be
permanently discarded.
Press 'X' to
acknowledge and
permanently destroy
the cached data.
The controller preserves
the dirty cache from a
virtual disk if the disk
becomes offline or is
deleted because of missing
physical disks. This
message indicates that
some configured disks were
removed. If the disks were
not removed, they are no
longer accessible. The SAS
cables for your system
might be improperly
connected.
Check the cable
connections and restart
the system.
Use the
<Ctrl><R>
utility to import the
virtual disk or discard
the preserved cache.
For the steps to
manage preserved
cache, see "Managing
Preserved Cache" on
page 96.
Entering the
configuration utility
in this state will
result in drive
configuration changes.
Press 'Y' to continue
loading the
configuration utility
or please power off
your system and check
your cables to ensure
all disks are present
and reboot.
The message is displayed
after another BIOS
warning indicating there
are problems with
previously configured disks
and you have chosen to
accept any changes and
continue.
The SAS cables for your
system might be
improperly connected.
Check the cable
connections and restart
the system.
If there are no cable
problems, press any key
or <Y> to continue.
Table 9-1. BIOS Errors and Warnings
(continued)
Error Message
Probable Cause
Corrective Action
PERC7.2_UG.book Page 134 Thursday, March 3, 2011 2:14 PM
Summary of Contents for PERC H700
Page 1: ...Dell PowerEdge RAID Controller PERC H700 and H800 User s Guide ...
Page 10: ...10 Contents ...
Page 14: ...14 Safety Instructions ...
Page 40: ...40 Storage Controller Features ...
Page 68: ...68 Installing and Configuring Hardware ...
Page 120: ...120 CacheCade ...
Page 130: ...130 Security Key and RAID Management ...
Page 152: ...152 Troubleshooting ...
Page 154: ...154 Regulatory Notices ...
Page 156: ...156 Corporate Contact Details Taiwan Only ...
Page 178: ...178 Index ...