138
Troubleshooting
The foreign
configuration message
is present during POST
but no foreign
configurations are
present in the foreign
view page in CTRL+R.
All virtual disks are
in an optimal state.
Ensure all your Physical
Disks (PD) are present
and all virtual disks are
in optimal state. Clear
the foreign
configuration using
<Ctrl><R>
or Dell
OpenManage Server
Administrator Storage
Management.
CAUTION:
The
physical disk goes to
Ready state when you
clear the foreign
configuration.
If you insert a physical
disk that was previously
a member of a virtual
disk in the system, and
that disk’s previous
location has been taken
by a replacement disk
through a rebuild, you
must manually remove
the foreign
configuration flag of
the newly inserted disk.
Previous
configuration(s)
cleared or missing.
Importing
configuration created
on XX/XX XX.XX. Press
any key to continue,
or ’C’ to load the
configuration utility.
The message indicates that
the controller and physical
disks have different
configurations.
You can use the BIOS
Configuration Utility
to clear the foreign
configuration.
Table 9-1. BIOS Errors and Warnings
(continued)
Error Message
Probable Cause
Corrective Action
PERC7.2_UG.book Page 138 Thursday, March 3, 2011 2:14 PM
Summary of Contents for PERC H700
Page 1: ...Dell PowerEdge RAID Controller PERC H700 and H800 User s Guide ...
Page 10: ...10 Contents ...
Page 14: ...14 Safety Instructions ...
Page 40: ...40 Storage Controller Features ...
Page 68: ...68 Installing and Configuring Hardware ...
Page 120: ...120 CacheCade ...
Page 130: ...130 Security Key and RAID Management ...
Page 152: ...152 Troubleshooting ...
Page 154: ...154 Regulatory Notices ...
Page 156: ...156 Corporate Contact Details Taiwan Only ...
Page 178: ...178 Index ...