112
Configuring and Managing RAID
3
Press <F2> to display a menu of available actions.
The
Rebuild
option is highlighted at the top of the menu.
Press the right-arrow key to display the rebuild options and select
Start
.
4
After you start the rebuild, press <Esc> to display the previous menu.
NOTE:
You can also use the VD Mgmt screen to perform a manual rebuild. Use the
arrow key to highlight a physical disk, and press <F2>. In the menu that is displayed,
select the Rebuild option.
CAUTION:
If a physical disk is a member of a disk group that contains multiple
virtual disks and one of the virtual disks is deleted when a rebuild operation is in
progress, the rebuild operation stops. You can then resume the rebuild operation
manually using a storage management application. To avoid interruption, ensure
that none of the virtual disks are deleted until the rebuild is complete.
Controller Management
Enabling Boot Support
NOTE:
See your system documentation to ensure the proper boot order is selected
in the system BIOS.
In a multiple controller environment, you can enable BIOS on multiple
controllers. However, if you want to boot from a specific controller, enable the
BIOS on that controller and disable it on the other controllers. The system
can then boot from the BIOS-enabled controller. Perform the following steps
to enable the controller BIOS:
1
Press <Ctrl><N> to access the
Ctrl Mgmt
menu screen.
2
Press <Tab> to move the cursor to
Enable Controller BIOS
in the
Settings
box.
3
Press the spacebar to select
Enable Controller BIOS
.
An
X
is displayed beside
Enable Controller BIOS
.
4
Press <Tab> to move the cursor to the
Apply
button, and then press
<Enter> to apply the selection.
The controller BIOS is enabled. To disable the controller BIOS, use the
spacebar to de-select the
Enable Controller BIOS
control, and then select
Apply
and press <Enter>.
PERC7.2_UG.book Page 112 Thursday, March 3, 2011 2:14 PM
Summary of Contents for PERC H700
Page 1: ...Dell PowerEdge RAID Controller PERC H700 and H800 User s Guide ...
Page 10: ...10 Contents ...
Page 14: ...14 Safety Instructions ...
Page 40: ...40 Storage Controller Features ...
Page 68: ...68 Installing and Configuring Hardware ...
Page 120: ...120 CacheCade ...
Page 130: ...130 Security Key and RAID Management ...
Page 152: ...152 Troubleshooting ...
Page 154: ...154 Regulatory Notices ...
Page 156: ...156 Corporate Contact Details Taiwan Only ...
Page 178: ...178 Index ...