6
To transfer the files to the RAID controller module without activating them, click
Transfer files but don't activate them (activate
later)
.
7
Click
Transfer
.
Keep these guidelines in mind:
•
If the
Transfer
button is inactive, ensure that you either select an NVSRAM file or clear the
Transfer NVSRAM file with RAID
controller module firmware
check box.
•
If the file selected is not valid or is not compatible with the current storage array configuration, the
File Selection Error
dialog is
displayed. Click
OK
to close it, and choose a compatible firmware or NVSRAM file.
8
In the
Confirm Download
dialog, click
Yes
.
The download starts.
9
If you are using the EMW, perform one of these actions:
•
Select
Tools
>
Upgrade RAID Controller Module Firmware
.
•
Select the
Setup
tab, and click
Upgrade RAID Controller Module Firmware
.
10 In the
Storage array
pane, select the storage array for which you want to upgrade the RAID controller module firmware or the
NVSRAM.
You can select more than one storage array.
NOTE:
The Details pane shows the details of only one storage array at a time. If you select more than one storage array in
the Storage Array pane, the details of the storage arrays are not shown in the Details pane.
11 Click
Firmware
in the
Download
area.
If you select a storage array that cannot be upgraded, the
Firmware
button is disabled. The
Download Firmware
dialog is displayed.
The current firmware version and the NVSRAM version of the selected storage arrays appear.
NOTE:
If you select the storage arrays with different RAID controller module types that cannot be updated with the same
firmware or NVSRAM file and click Firmware, the Incompatible RAID Controller Modules dialog is displayed. Click OK to
close the dialog and select the storage arrays with similar RAID controller module types.
12 To locate the directory in which the file to download resides, click
Browse
in the
Select files
area.
The
Select File
dialog is displayed.
13 Select the file to download.
14 Click
OK
.
15 If you want to download the NVSRAM file with the RAID controller module firmware, select
Download NVSRAM file with firmware
in
the
Select files
area.
Any attributes of the firmware file are displayed in the Firmware file information area. The attributes indicate the version of the
firmware file.
Any attributes of the NVSRAM file are displayed in the NVSRAM file information area. The attributes indicate the version of the
NVSRAM file.
16 If you want to download the file and activate the firmware and NVSRAM later, select the
Transfer files but don’t activate them
(activate later)
check box.
NOTE:
If any of the selected storage arrays do not support downloading the files and activating the firmware or NVSRAM
later, the Transfer files but don’t activate them (activate later) check box is disabled.
17 Click
OK
.
The
Confirm Download
dialog is displayed.
18 Click
Yes
.
The download starts and a progress indicator is displayed in the Status column of the
Upgrade RAID Controller Module Firmware
window.
Downloading only NVSRAM firmware
Use the command line interface (CLI) to download and activate NVSRAM to several storage arrays.
Management firmware downloads
165