Installation 

Section 2

Location

The location selected for the equipment must meet the 

following criteria. If any of these criteria are not met, select 

another location.
•  Units are intended for indoor use only.
•  The location MUST be level, stable and capable of 

supporting the weight of the equipment.

•  The location MUST be free from and clear of 

combustible materials.

•  Equipment MUST be level both front to back and side to 

side.

•  Position the equipment so it will not tip or slide.
•  Recommended air temperature is 41° - 86°F (5° - 30°C).
•  Proper air supply for ventilation is REQUIRED AND 

CRITICAL for safe and efficient operation. Refer to 

Clearance Requirements chart on page 12.

•  Do not obstruct the flow of ventilation air. Make sure the 

air vents of the equipment are not blocked.

•  Do not install the equipment directly over a drain. 

Steam rising up out of the drain will adversely affect 

operation, air circulation, and damage electrical / 
electronic components.

Weight Of Equipment

Model

Ship Weight 

8100-EFP Series

8118-EFP

169lbs (77kg)

8132-EFP

215lbs (98kg)

8145-EFP

265lbs (120kg)

8159-EFP

285lbs (130kg)

8172-EFP

295lbs (134kg)

8186-EFP

394lbs (179kg)

8100-EF-E Export Series

8118-EF-E

169lbs (77kg)

8132-EF-E

215lbs (98kg)

8145-EF-E

265lbs (120kg)

8159-EF-E

285lbs (130kg)

8172-EF-E

295lbs (134kg)

8186-EF-E

394lbs (179kg)

8100-EFNP Series

8148-EFNP

235lbs (107kg)

8169-EFNP

285lbs (130kg)

8191-EFNP

295lbs (134kg)

8100-EFN-E Export Series

8148-EFN-E

235lbs (107kg)

8169-EFN-E

285lbs (130kg)

8191-EFN-E

295lbs (134kg)

N8000 Series

N8018

38lbs (17kg)

N8030

84lbs (38kg)

N8043

110lbs (50kg)

N8056

139lbs (63kg)

N8069

160lbs (73kg)

N8081

197lbs (89kg)

N8000N Series

N8046N

100lbs (45kg)

N8068N

120lbs (55kg)

N8000-R Series

N8044-R

100lbs (45kg)

N8059-R

118lbs (53kg)

N8076-R

145lbs (65kg)

N8094-R

164lbs (74kg)

N8100BP Series

N8118BP

100lbs (45kg)

N8130BP

140lbs (64kg)

N8143BP

173lbs (78kg)

N8156BP

205lbs (93kg)

N8169BP

225lbs (102kg)

N8181BP

258lbs (117kg)

N8100B-E Export Series - R404A

N8118B-E

100lbs (45kg)

N8130B-E

140lbs (64kg)

N8143B-E

173lbs (78kg)

N8100B-E Export Series - R134A

N8156B-E

205lbs (93kg)

N8169B-E

225lbs (102kg)

N8100BRP Series

N8144-BRP

161lbs (72kg)

N8159-BRP

184lbs (83kg)

N8176-BRP

233lbs (105kg)

N8194-BRP

243lbs (109kg)

Summary of Contents for N8018

Page 1: ...00N N8000 R N8100BP N8100 BRP N8100 FAP N8200P N8200GP N8200 STP N8600P N8700 D N8700 DESP N8700 R N8800 Installation Operation and Maintenance Manual Original Document Caution Read this instruction b...

Page 2: ...dures for all utilities including electric gas water and steam nWarning This product contains chemicals known to the State of California to cause cancer and or birth defects or other reproductive harm...

Page 3: ...frigerated Drop In Units 24 8600P Self Contained Combo Hot Cold Drop In Units 26 8700 Hot Food Well Drop In Units 28 Electrical Service 29 Voltage 29 Ground Fault Circuit Interrupter 29 Rated Amperage...

Page 4: ...EV00 11 19 Table of Contents continued N8700 DESP Operation 41 Section 4 Maintenance Cleaning and Sanitizing Procedures 42 General 42 Exterior Cleaning 43 Cleaning the Condenser Coil 43 N8100 FA Serie...

Page 5: ...ries Self Contained Mechanically Cooled Pans Narrow Style R404A N8146NB E N8168NB E N8200P Series Self Contained Frost Tops R290 N8231P N8245P N8259P N8273P N8287P N8200 E Export Series Self Contained...

Page 6: ...ote panel Always have the serial number of your unit available when calling for parts or service Warranty Information Register your product for warranty Verify warranty information View and download a...

Page 7: ...ce without depending on or transmitting stress to the electrical conduit nWarning To avoid instability the installation area must be capable of supporting the combined weight of the equipment and prod...

Page 8: ...ent Model Ship Weight 8100 EFP Series 8118 EFP 169lbs 77kg 8132 EFP 215lbs 98kg 8145 EFP 265lbs 120kg 8159 EFP 285lbs 130kg 8172 EFP 295lbs 134kg 8186 EFP 394lbs 179kg 8100 EF E Export Series 8118 EF...

Page 9: ...8643P 198lbs 90kg N8656P 233lbs 106kg N8669P 266lbs 121kg N8681P 301lbs 137kg N8700D Series N8717 D 41lbs 19kg N8731 D 99lbs 45kg N8745 D 134lbs 61kg N8759 D 166lbs 75kg N8773 D 186lbs 84kg N8787 D 23...

Page 10: ...26 66cm 10 75 27cm 5 N8081 81 75 208cm 26 66cm 10 75 27cm 6 Model Length Depth Height 12x20 Pans N8000N Series N8046N 46 75 119cm 18 46cm 10 75 27cm 2 N8068N 67 5 171cm 18 46cm 10 75 27cm 3 N8000 R Se...

Page 11: ...8240 STP 39 70 101cm 29 60 75cm 15 70 40cm NA N8256 STP 55 60 141cm 22 56cm 15 70 40cm NA N8258 STP 57 60 146cm 29 60 75cm 15 70 40cm NA N8275 STP 75 50 192cm 29 60 75cm 15 70 40cm NA Model Length Dep...

Page 12: ...cm 9 5 24cm 5 14 Overall height including drain connection N8800 Series N8831 31 75 81cm 26 66cm 11 28cm 2 N8845 45 63 116cm 26 66cm 11 28cm 3 N8859 59 5 151cm 26 66cm 11 28cm 4 N8873 73 38 186cm 26 6...

Page 13: ...ries N8018 17 x 25 43cm x 64cm NA N8030 29 75 x 25 76cm x 64cm NA N8043 42 5 x 25 108cm x 64cm NA N8056 55 25 x 25 140cm x 64cm NA N8069 68 x 25 173cm x 64cm NA N8081 80 75 x 25 205cm x 64cm NA Model...

Page 14: ...149cm x 64cm NA N8200 STP Series N8230 STP 28 60 x 21 10 73cm x 54cm NA N8240 STP 38 65 x 28 75 98cm x 73cm NA N8256 STP 54 60 x 21 10 139cm x 54cm NA N8258 STP 56 60 x 28 75 144cm x 73cm NA N8275 ST...

Page 15: ...ND 44 62 x 15 0 113cm x 38cm 10 31 x 4 62 x 7 26cm x 12cm x 18cm N8768N 66 50 x 15 0 169cm x 38cm 14 50 x 4 62 x 7 37cm x 12cm x 18cm N8768ND 66 50 x 15 0 169cm x 38cm 14 50 x 4 62 x 7 37cm x 12cm x 1...

Page 16: ...50 17 06 43cm 17 06 43cm 19 50 50cm 17 06 43cm 19 50 50cm 25 10 64cm 25 10 64cm 85 172 50 172 50 172 50 172 50 85 95 95 15 67 40cm 15 67 40cm 13 78 35cm 25 00 64cm 13 78 35cm 13 78 35cm 25 00 64cm 25...

Page 17: ...rain on N8000 N8000N N8000 R models is shipped loose and must be connected during installation A Provided 1 25mm drain nut and washer must be field installed to an appropriate container or floor drain...

Page 18: ...29 75 76cm 42 5 108cm E 25 64cm 25 64cm 25 64cm F Min 2 75 7cm Max 4 75 12cm Dimension N8156BP N8169BP N8181BP A 55 25 140cm 68 173cm 80 75 205cm B 27 75 70cm 27 75 70cm 27 75 70cm C 26 66cm 26 66cm...

Page 19: ...and washer must be field installed to an appropriate container or floor drain following local code requirements Sinks come standard with 1 1 2 basket strainer assemblies B Remove drill foam out of dra...

Page 20: ...cm 25 64cm 25 64cm F Min 2 75 7cm Max 4 75 12cm Dimension N8159 EFP N8172 EFP N8186_EFP A 57 87 147cm 71 5 182cm 85 216cm B 27 75 70cm 27 75 70cm 27 75 70cm C 26 66cm 26 66cm 26 66cm D 57 87 147cm 71...

Page 21: ...washer must be field installed to an appropriate container or floor drain following local code requirements Sinks come standard with 1 1 2 basket strainer assemblies B Remove drill foam out of drain h...

Page 22: ...81 25 206cm B 27 75 70cm 27 75 70cm 27 75 70cm C 26 66cm 26 66cm 26 66cm D 55 75 142cm 68 5 174cm 81 25 206cm E 25 5 65cm 25 5 65cm 25 5 65cm F Min 2 75 7cm Max 4 75 12cm G 15 75 H 23 50 3 Place the...

Page 23: ...s use a fork to hold the drain in place if necessary G Clean up excess plumbers putty 8 Inside the well the fan assembly has standoff brackets with tabs The tabs should be bent up 9 Place the coil ass...

Page 24: ...C 26 66cm 26 66cm D 72 38 184cm 86 25 219cm E 25 64cm 25 64cm F Min 2 75 7cm Max 4 75 12cm Dimension N8230 STP N8240 STP N8256 STP A 28 6 73cm 38 65 98cm 54 6 139cm B 27 75 70cm 27 75 70cm 27 75 70cm...

Page 25: ...n N8200P N8200 GP and N8200 STP models is shipped loose and must be connected during installation A Provided 1 25mm drain nut and washer must be field installed to an appropriate container or floor dr...

Page 26: ...75 205cm 101 75 258cm E 25 64cm 25 64cm 25 64cm F 4 75 12cm Min 2 75 7cm Max 4 75 12cm 2 Place the condensing unit through the counter cutout 3 Extend the telescoping duct from the front of the conde...

Page 27: ...warranty Louver measures 20 00 x 25 00 51cm x 64cm Louver Cutout Size is 18 50 x 22 50 47cm x 57cm typical installation Finned Coil Duct Partitions Not Shown Louver Suggested Drainage Trap Units may i...

Page 28: ...or the knobs will control the opposite wells Drains Control panel installed opposite drains Infinite control shown directions also apply to digital control 3 Place the control panel into the cutout fr...

Page 29: ...t as they are known for more intermittent nuisance trips than panel breakers Not These appliances will operate within the marked rated voltage range without adjustment RATED AMPERAGES HORSEPOWER VOLTA...

Page 30: ...D 208 230 60 1 29 0 32 0 NA Hard Wire Model V Hz Ph Amps H P Plug N8700D E Export Series N8717 D E 240 50 1 6 0 Amps 1450 Watts NA Hard Wire N8731 D E 240 50 1 12 1 Amps 2900 Watts NA Hard Wire N8745...

Page 31: ...BRP 889 24 51 13 1192 120g N8194 BRP 1108 28 47 9 1297 120g N8100 FAP Series N8131 FAP 996 144 16 18 2354 150g N8144 FAP 1137 144 16 18 2354 150g N8157 FAP 2294 289 16 18 4749 150g N8169 FAP 2412 289...

Page 32: ...8800 MODELS 1 Locate mounting holes on outside operator drop in body and mount float and bracket using thumb screws 2 Install drain plumbing as shown 3 Connect clear plastic tubing to 1 2 copper stub...

Page 33: ...erator drop in body and mount float and bracket using thumb screws 2 Install drain plumbing as shown 3 Connect clear plastic tubing to 1 2 copper stub and connect to the float Use hose clamps to secur...

Page 34: ...to keep the air grills clear will result in unsatisfactory operation of the system Caution Units with pans should be operated with pans in place Operating the unit without all pans in place will lower...

Page 35: ...t purposes only Display does not reflect air or product temps in unit TEMPERATURE CONTROL DISPLAY V V Operation Indication Status Displayed Comments Normal C Temp C Unit depends on setting parameters...

Page 36: ...then start up in normal cooling mode Temperature Alarm The alarm will sound and flash HI or LO 90 minutes after the unit has reached its alarm temperature point or after any power interruption if the...

Page 37: ...ture of the cold pan The control is located in the machine compartment To turn the cold pan off turn the knob to the off position The unit must be turned off when not in use or overnight for defrostin...

Page 38: ...turned off when not in use or overnight for defrosting and cleaning 8600P Hot Cold Series Operation Hot Operation DANGER When operated at the highest temperature setting the top of the unit will beco...

Page 39: ...ow the immersion heater to cool and the safety switch will automatically reset The unit must be turned OFF as directed or safety switch will not reset even if water is refilled to proper level Replace...

Page 40: ...ected skin to contact any well surface Wet operation is usually much more efficient and is preferred However these units may be operated without water with no damage to the unit When operated dry the...

Page 41: ...of the bains marie Fill the food well with a minimum of 2 5cm of water and cover with lid or empty pan To preheat water set temperature control at 3 With pans in place wells will boil water Food temp...

Page 42: ...n nWarning Never use sharp objects or tools to remove ice or frost Do not use mechanical devices or other means to accelerate the defrosting process Cleaning and Sanitizing Procedures Caution Maintena...

Page 43: ...steel N8600P Immersion Heater Follow the same as instructions as the rest of the food well Wipe surfaces with a damp cloth rinsed in water to remove dust and dirt from the unit If a greasy residue pe...

Page 44: ...DELFIELD 980 SOUTH ISABELLA ROAD MOUNT PLEASANT MI 48858 800 733 8821 WWW DELFIELD COM 2019 Welbilt Inc except where explicitly stated otherwise All rights reserved Part Number 9291458 Rev00 11 19...

Reviews: