Part Number: 9291458 REV00 12/19 25
Section 2
Installation
Use Screws to Secure Desired Depth
3 of 8 Screws Shown
6. Partitions must fully extend front to back and top to
bottom.
7. Louver cutout must extend to bottom of cabinet and
align with condenser face.
NOTE: The louver provided must be installed in front of
the condensing unit’s finned coil. Any restriction to the
proper air flow will void the compressor warranty.
• Louver measures 13.00” x 25.00” (33cm x 64cm).
• Louver Cutout Size is 11.50” x 22.50” (29cm x 57cm)
(typical installation).
Finned C
oil
Duct
Partitions Not Shown
Louv
er
Typical Counter Cabinet
8. The 1” diameter drain on N8200P, N8200-GP and
N8200-STP models is shipped loose and must be
connected during installation.
A. Provided 1” (25mm) drain, nut and washer must
be field installed to an appropriate container or
floor drain following local code requirements.
Sinks come standard with 1-1/2” basket strainer
assemblies.
B. Remove/drill foam out of drain hole.
C. Apply thin ring of plumbers putty around the
drain.
D. From the inside drop the drain into the drain hole.
E. From the outside secure the drain with the washer
and nut.
F. Tighten the nut with channel locks, use a fork to
hold the drain in place if necessary.
G. Clean up excess plumbers putty.
Suggested Drainage Trap
Units may increase in performance if they have a
drainage trap or shut-off valve installed. Installing the
trap will stop warm air being introduced into the dry
well of the unit.