Part Number: 9291458 REV00 12/19 35
Section 3
Operation
8100-EF(N)P & 8100-FAP Series Operation
Note
The cold pan is not intended to be used with ice.
There is a switch on the compressor housing front to turn
the 8100-EFP units on and off. The unit must be turned off
when not in use or overnight for defrosting and cleaning.
8100-EFP Series LiquiTec® Eutetic fluid cold pans are
adjusted at the factory to provide proper operation without
any further adjustments.
The temperature control is located on the condensing
housing.
Power Switch & Temperature Control
1. At initial start-up or anytime power is disconnected,
then reconnected to the unit, the control will go into
normal cooling mode.
2. The temperature control will cycle the compressor and
condenser fan motor to maintain proper temperature.
Notice
Temperature displayed is for refrigeration set point
purposes only. Display does not reflect air or product
temps in unit.
TEMPERATURE CONTROL & DISPLAY
V
V
Operation / Indication
Status
Displayed
Comments
Normal (°C)
Temp. [°C]
Unit depends on setting
(parameters in control)
Normal (°F)
Temp. [°F]
Show set-point
Temp.
Sensor 1 defect
E01
X
Air sensor
Sensor 2 defect
E02
X
Coil sensor
Sensor 3 defect
E03
X
Open
Sensor 4 defect
E04
X
Open
High temperature
alarm
Hi
X Automatically switching
at 2 sec rate
Low temperature alarm
Lo
X
Line voltage too high,
above 140 volts
uHi
X
Line voltage too low,
below 96 volts
uLi
X
Control calls for cooling
for more than 24 hours
straight
LEA
X
Time includes defrost.
Error will go away if the
control cycles off the
compressor or if the
power is shut off. If error
is on a cold pan it could
be related to a high
ambient temperature or
not shutting the rail off
nightly.
All alarms sound for approximately 10 seconds and then
are silent for 50 seconds. It will do that for 15 cycles and
then remain silent. The alarm code will still be present on
the display until the fault clears.