Part Number: 9291458 REV00 12/19 29
Section 2
Installation
Electrical Service
DANGER
Check all wiring connections, including factory
terminals, before operation. Connections can become
loose during shipment and installation.
n
Warning
This appliance must be grounded and all field wiring
must conform to all applicable local and national
codes. Refer to rating plate for proper voltage. It is the
responsibility of the end user to provide the disconnect
means to satisfy the authority having jurisdiction.
VOLTAGE
All electrical work, including wire routing and grounding,
must conform to local, state and national electrical codes.
The following precautions must be observed:
• The equipment must be grounded.
• A separate fuse/circuit breaker must be provided for
each unit.
• A qualified electrician must determine proper wire size
dependent upon location, materials used and length
of run (minimum circuit ampacity can be used to help
select the wire size).
• The maximum allowable voltage variation is ±10% of
the rated voltage at equipment start-up (when the
electrical load is highest).
• Check all green ground screws, cables and wire
connections to verify they are tight before start-up.
GROUND FAULT CIRCUIT INTERRUPTER
Ground Fault Circuit Interrupter (GFCI/GFI) protection is
a system that shuts down the electric circuit (opens it)
when it senses an unexpected loss of power, presumably
to ground. Manitowoc does not recommend the use of
GFCI/GFI circuit protection to energize our equipment. If
code requires the use of a GFCI/GFI then you must follow
the local code. The circuit must be dedicated, sized
properly and there must be a panel GFCI/GFI breaker. We
do not recommend the use of GFCI/GFI outlets to energize
our equipment as they are known for more intermittent
nuisance trips than panel breakers.
Note
These appliances will operate within the marked rated
voltage range without adjustment.
RATED AMPERAGES, HORSEPOWER, VOLTAGE &
POWER CORD CHART
Units with plugs are supplied with approximately 6ft
(183cm) cords.
Model
V, Hz, Ph
Amps
H.P.
Plug
8100-EFP Series R290
8118-EFP
115, 60, 1
2.4
1/5 NEMA 5-15P
8132-EFP
115, 60, 1
2.4
1/5 NEMA 5-15P
8145-EFP
115, 60, 1
3.7
1/4 NEMA 5-15P
8159-EFP
115, 60, 1
3.7
1/4 NEMA 5-15P
8172-EFP
115, 60, 1
4.8
1/3 NEMA 5-15P
8186-EFP
115, 60, 1
4.8
1/3 NEMA 5-15P
8100-EF-E Export Series
8118-EF-E
230-240, 50, 1
2.5 Amps /
600 Watts
1/4
Varies Per
Destination
8132-EF-E
8145-EF-E
8159-EF-E
8172-EF-E
8186-EF-E
8100-EFNP Series R290
8148-EFNP
115, 60, 1
2.4
1/5
NEMA 5-15P
8169-EFNP
3.7
1/4
8191-EFNP
4.8
1/3
8100-EFN-E Export Series
8148-EFN-E
230-240, 50, 1
2.5 Amps /
600 Watts
1/4
Varies Per
Destination
8169-EFN-E
8191-EFN-E
N8000 Series - NA
N8000N Series - NA
N8000-R Series - NA
N8100BP Series - R290
N8118BP
115, 60, 1
2.0
1/5 NEMA 5-15P
N8130BP
115, 60, 1
2.0
1/5 NEMA 5-15P
N8143BP
115, 60, 1
3.1
1/4 NEMA 5-15P
N8156BP
115, 60, 1
3.1
1/4 NEMA 5-15P
N8169BP
115, 60, 1
3.1
1/4 NEMA 5-15P
N8181BP
115, 60, 1
4.6
1/3 NEMA 5-15P
N8100B-E Export Series - R404A
N8118B-E
230-240, 50, 1 1.5 Amps /
360 Watts
1/5
Varies Per
Destination
N8130B-E
N8143B-E
N8100B-E Export Series - R134A
N8156B-E
230-240, 50, 1
2.5 Amps /
600 Watts
1/4
Varies Per
Destination
N8169B-E
N8100BRP Series - R290
N8144-BRP
115, 60, 1
2.4
1/5 NEMA 5-15P
N8159-BRP
115, 60, 1
3.7
1/4 NEMA 5-15P
N8176-BRP
115, 60, 1
3.7
1/4 NEMA 5-15P
N8194-BRP
115, 60, 1
3.7
1/4 NEMA 5-15P
N8100-FAP Series - R290
N8131-FAP
115, 60, 1
4.7
1/4 NEMA 5-15P
N8144-FAP
115, 60, 1
4.7
1/4 NEMA 5-15P
N8157-FAP
115, 60, 1
9.3
1/2 NEMA 5-15P
N8169-FAP
115, 60, 1
9.3
1/2 NEMA 5-15P
N8182-FAP
115, 60, 1
9.3
1/2 NEMA 5-15P
N8100NB Series - R290
N8146NBP
115, 60, 1
2
1/5 NEMA 5-15P
N8168NBP
115, 60, 1
3.1
1/4 NEMA 5-15P